Cohere Beauty Holdings LLC
11222 I St, Omaha, Nebraska, United States
FEI 1931071
FDA has 5 inspections on file for Cohere Beauty Holdings LLC in Omaha, Nebraska (FEI 1931071), from 2008 to 2019. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Eight regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 5, 2008–2019
- 0 OAI · 4 VAI · 1 NAI
- Inspections with 483 observations shown
- 5 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful and specific test methods.
Sample identification and other information
Laboratory records do not include a description of the sample received for testing, the lot number or other distinctive code of the sample, the date the sample was taken and the date the sample was received for testing.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Following/documenting laboratory controls
Established test procedures and laboratory control mechanisms are not followed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Show 1 more citation
Lab controls established, including changes
The establishment of test procedures including any changes thereto, are not reviewed and approved by the quality control unit.
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Test methods
The accuracy, sensitivity and specificity of test methods have not been established and documented.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Mfg / Processing Operations Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
Show 1 more citation
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful and specific test methods.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.
Review of representative number of batches
Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Show 1 more citation
Testing Calculations
Laboratory records are deficient in that they do not include all calculations performed during testing.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, and packing of a drug product lack the education, training, and experience required to perform their assigned functions.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Valid stability test methods
The written stability program for drug products does not include meaningful test methods.
Show 4 more citations
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Identity of major equipment and lines used
Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Items to cover on annual reviews
Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Show 4 more citations
Identification of persons involved, each significant step
Batch production and control records do not include the identification of the persons directly supervising and checking each significant step in the operation, for each batch of drug product produced.
Written program not followed
The written stability testing program is not followed.
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Regulations FDA cited here
The 15 sections of 21 CFR in FDA’s published citations for this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 211.166Stability testing4 of 5
- 21 CFR 211.67Equipment cleaning and maintenance3 of 5
- 21 CFR 211.100Written procedures; deviations3 of 5
- 21 CFR 211.180General requirements3 of 5
- 21 CFR 211.188Batch production and control records3 of 5
- 21 CFR 211.192Production record review3 of 5
- 21 CFR 211.194Laboratory records3 of 5
- 21 CFR 211.22Responsibilities of quality control unit2 of 5
Show all 15
- 21 CFR 211.25Personnel qualifications2 of 5
- 21 CFR 211.165Testing and release for distribution2 of 5
- 21 CFR 211.186Master production and control records2 of 5
- 21 CFR 211.42Design and construction features1 of 5
- 21 CFR 211.160General requirements1 of 5
- 21 CFR 211.170Reserve samples1 of 5
- 21 CFR 211.198Complaint files1 of 5
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1931071 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1931071. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.