Skip to content

EPM Packaging, Inc.

210 E 4th St, Lexington, Nebraska, United States

FEI 1930466

FDA has 9 inspections on file for EPM Packaging, Inc. in Lexington, Nebraska (FEI 1930466), from 2010 to 2025. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Two of the five FOIA requests for this site have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: 21 CFR 211.100(a).

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
9, 2010–2025
2 OAI · 3 VAI · 4 NAI
Inspections with 483 observations shown
3 of 9
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
5 requests, latest FY2023
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction and location to facilitate cleaning, maintenance, and proper operations.

    2. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    3. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    4. Penicillin processing area not kept separate

      The operations relating to the packing of penicillin are not performed in facilities separate from those used for other drug products for human use.

    5. Training--operations, GMPs, written procedures

      Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.

    Show 3 more citations
    1. Written procedures lacking for use of pesticides etc.

      Written procedures are lacking for the use of designed to prevent the contamination of.

    2. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    3. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. In-Process and Laboratory Control Results

      The batch production and control records are deficient in that they do not include in-process control results.

    2. Representative Samples

      Representative samples are not taken of each shipment of each lot of drug product containers and closures for testing or examination.

    3. Absence of Written Procedures

      Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Manufacturing Instructions and Specifications

      The master production and control records are deficient in that they do not include complete manufacturing, control, instructions, sampling, testing, and procedures.

    2. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies.

  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on FY2023. Each one asked for a Form 483.

  • Inspection ending Aug 22, 2025OAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Mar 3, 2026. FDAgent holds no copy that FDA posted.

    1. Feb 24, 2026FDA-FOIA-2026-1913Form 483· 1 of 5 sitesRecords released
    2. Date not givenFDA-FOIA-2026-1663Form 483· 1 of 5 sitesRecords released
  • Inspection ending Jun 13, 2025OAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Oct 9, 2025. FDAgent holds no copy that FDA posted.

    1. May 5, 2026FDA-FOIA-2026-4429Form 483· 1 of 5 sitesRecords released
    2. Sep 8, 2025FDA-FOIA-2025-10724Form 483· 1 of 4 sitesRecords released
  • Inspection ending Jan 12, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. FY2023FDA-FOIA-2023-1060Form 483· 1 of 5 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 9 inspections, with how many of them cited each.

Show all 11

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1930466 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1930466. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.