Lloyd Inc. of Iowa
604 W Thomas Ave, Shenandoah, Iowa, United States
FEI 1911196DUNS 007281942
FDA has 9 inspections on file for Lloyd Inc. of Iowa in Shenandoah, Iowa (FEI 1911196), from 2010 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. Two of the four FOIA requests for this site have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Apr 16, 2013. FDA issued a warning letter on (CVM). No court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for analysis, through Dec 31, 2027. Its registrant is LLOYD, Inc. of Iowa (D-U-N-S 007281942).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 9, 2010–2025
- 1 OAI · 6 VAI · 2 NAI
- Inspections with 483 observations shown
- 4 of 9
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 4 requests, latest Jan 30, 2026
- Warning letters
- · CVM ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing Containers & Closures Conformity with Specs
Containers and closures are not tested for conformance with all appropriate written procedures.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not reviewed and approved by the quality control unit.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
In-process samples representative, identified properly
Samples taken of in-process materials for determination of conformance to specifications are not representative.
Calibration - at intervals, written program, remedial action
The calibration of instruments, gauges, and recording devices is not done at suitable intervals in accordance with an established written program.
Show 5 more citations
Control procedures to monitor and validate performance
Control procedures are not established which of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing of the drug product.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful, and specific test methods.
Test methods
The sensitivity, specificity, and reproducibility of test methods have not been established and documented.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Inadequate number of personnel
The number of qualified personnel is inadequate to perform and supervise the manufacture, processing, packing, and holding of each drug product.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.
Show 8 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Lab controls established, including changes
The establishment of laboratory control mechanisms including any changes thereto, are not reviewed and approved by the quality control unit.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
In-process sample representation/identification
In-process samples are not representative.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complaint Investigation/Follow-Up Findings
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Rejected in-process materials not quarantined
Rejected in-process materials are not identified and controlled under a quarantine system to prevent their use in manufacturing or processing operations for which they are unsuitable.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy did not extend to other batches of the same drug product.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on Jan 30, 2026. Each one asked for a Form 483.
Inspection ending Nov 6, 2025VAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Feb 10, 2026. FDAgent holds no copy that FDA posted.
- Jan 30, 2026FDA-FOIA-2026-897Form 483Records released
- Jan 9, 2026FDA-FOIA-2026-311Form 483· 1 of 5 sitesRecords released
Inspection ending Sep 15, 2023VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Feb 27, 2025FDA-FOIA-2025-1812Form 483Closed
- Dec 28, 2023FDA-FOIA-2023-11533Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 9 inspections, with how many of them cited each.
- 21 CFR 211.100Written procedures; deviations3 of 4
- 21 CFR 211.198Complaint files3 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 4
- 21 CFR 211.160General requirements2 of 4
- 21 CFR 211.165Testing and release for distribution2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.194Laboratory records2 of 4
Show all 16
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.63Equipment design, size, and location1 of 4
- 21 CFR 211.103Calculation of yield1 of 4
- 21 CFR 211.166Stability testing1 of 4
- 21 CFR 211.170Reserve samples1 of 4
- 21 CFR 211.180General requirements1 of 4
- 21 CFR 314.81Other postmarketing reports1 of 4
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCVM · VeterinaryFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
FDA drug establishment registration
FDA registration search- Registered operations
- Analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- LLOYD, Inc. of IowaD-U-N-S 007281942
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1911196 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1911196. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.