FDA has 3 inspections on file for New Vistas Incorporated in Denver, Colorado (FEI 1721460), from 2009 to 2013. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2009–2013
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Homeopathic drugs, assessment of stability
There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients.
Complaints reviewed by Quality Control Unit
Written procedures describing the handling of complaints do not include provisions for a determination as to the need for an investigation of any unexplained discrepancy.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Show 1 more citation
Component written specification
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance23 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
In-process materials characteristics testing
In-process materials are not tested for strength and quality and approved or rejected by the quality control unit during the production process and after storage for long periods.
Testing and standardization of standards et. al.
Laboratory records do not include complete records of any testing and standardization of laboratory reference standards, reagents, and standard solutions.
Objectionable microbiological contamination
Each lot of a component liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Theoretical yield statement including percentages
Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required.
Show 18 more citations
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Weight or measure of each component
The master production and control records lack an accurate statement of the measure of each component using the same weight system for each component.
Lab controls established, including changes
The establishment of test procedures including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
In process materials - conformance to written specs
Laboratory controls do not include a determination of conformance to written specifications for in-process materials.
Retesting when subject to deterioration
Procedures designed to assure conformance to written specifications do not require appropriate retesting of components subject to deterioration.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, returned or salvaged drug products, and investigations conducted for each drug product.
Sampling and testing plans not followed
Written procedures for sampling and testing plans are not followed for each drug product.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Microbiological testing
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Homeopathic drugs, assessment of stability
There is no written assessment of stability of homeopathic drug products based at least on testing or examination of the drug product for compatibility of the ingredients and marketing experience with the drug product to indicate that there is no degradation of the product for the normal or expected period of use.
Approve or reject procedures or specs
The quality control unit lacks responsibility to reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Supervisor Training/Education/Experience
Individuals responsible for supervising the manufacture and processing of a drug product lack the education and training to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components, in-process materials, and drug products are not available to the quality control unit.
Record maintenance 3 years (exempt OTC drugs)
Records for all production and components associated with a batch of OTC drug product which is exempt from expiration dating are not maintained for 3 years after distribution of the last lot of drug product.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Following/documenting laboratory controls
Established specifications are not followed.
Sampling and testing plans not followed
Written procedures for sampling and testing plans are not followed for each drug product.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.100Written procedures; deviations3 of 3
- 21 CFR 211.160General requirements3 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.165Testing and release for distribution2 of 3
- 21 CFR 211.166Stability testing2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
Show all 14
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.186Master production and control records1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.194Laboratory records1 of 3
- 21 CFR 211.198Complaint files1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1721460 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1721460. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.