K.W. Griffen Company
100 Pearl St, Norwalk, Connecticut, United States
FEI 1211177DUNS 622463388
FDA has 6 inspections on file for K.W. Griffen Company in Norwalk, Connecticut (FEI 1211177), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Three FOIA requests have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.192 and 21 CFR 211.84(d)(2).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for relabeling and repacking, through Dec 31, 2026. Its registrant is K. W. Griffen Company (D-U-N-S 018665224).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2009–2025
- 0 OAI · 4 VAI · 2 NAI
- Inspections with 483 observations shown
- 4 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest May 18, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Approve or reject components, products
The quality control unit lacks the responsibility and authority to approve and reject all drug products.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Show 1 more citation
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Incomplete periodic safety report
You failed to submit a periodic report containing a narrative summary and analysis of the ADE information for the reporting interval in the report and a history of actions taken since the last report because of adverse drug experiences.
Failure to maintain records
You failed to maintain for a period of 10 years records of all adverse drug experiences known to you, including raw data and any correspondence.
Interval
Periodic reports of non-alert adverse drug experiences have not been submitted yearly for an application which was approved three or more years ago.
Timely submission
An annual report was not submitted each year to the FDA division responsible for reviewing the application.
Failure to develop written procedures
Written procedures have not been developed for the surveillance, receipt, evaluation and reporting to FDA of post marketing adverse drug experiences.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.
Active ingredient retained sample kept
A sample which is representative of each lot in each shipment of each active ingredient is not retained.
Equipment for Environmental Control
Equipment for adequate control over temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
Show 2 more citations
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Containers sampled so as to prevent contamination
Containers are not opened, sampled and resealed in a manner designed to prevent contamination of their contents, other components and other drug product containers or closures.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDevices · Compliance: Devices3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sampling and testing plans not followed
Written procedures for sampling and testing plans are not followed for each drug product.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on May 18, 2026. Each one asked for a Form 483.
Inspection ending May 16, 2025VAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Aug 5, 2025. FDAgent holds no copy that FDA posted.
- May 18, 2026FDA-FOIA-2026-5054Form 483· 1 of 5 sitesWithdrawn
- Nov 17, 2025FDA-FOIA-2025-13045Form 483· 1 of 4 sitesRecords released
- Jul 1, 2025FDA-FOIA-2025-8119Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 4
- 21 CFR 211.170Reserve samples2 of 4
- 21 CFR 211.192Production record review2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 4
- 21 CFR 211.63Equipment design, size, and location1 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.100Written procedures; deviations1 of 4
Show all 14
- 21 CFR 211.113Control of microbiological contamination1 of 4
- 21 CFR 211.122Materials examination and usage criteria1 of 4
- 21 CFR 211.160General requirements1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
- 21 CFR 314.80Postmarketing reporting of adverse drug experiences1 of 4
- 21 CFR 314.81Other postmarketing reports1 of 4
FDA drug establishment registration
FDA registration search- Registered operations
- Relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- K. W. Griffen CompanyD-U-N-S 018665224
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1211177 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1211177. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.