Skip to content

Crown Laboratories

349 Lafe Cox Dr, Johnson City, Tennessee, United States

FEI 1019820DUNS 119508400

FDA has 8 inspections on file for Crown Laboratories in Johnson City, Tennessee (FEI 1019820), from 2011 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. One FOIA request has asked FDA for this inspection's 483.

The most recent OAI inspection ended on Sep 24, 2014. FDA's compliance record also lists one other action under this FEI: Injunction, . 1 import refusal is filed under this FEI, on . No warning letter is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.110(a) and 21 CFR 211.22(d).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2027. Its registrant is Crown Laboratories (D-U-N-S 079035945).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
8, 2011–2025
1 OAI · 5 VAI · 2 NAI
Inspections with 483 observations shown
5 of 8
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest Dec 22, 2025
Warning letters
None on file
Import refusals
1 refusal
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

    2. FDCA 760(b)(1)

      Failure of responsible person to report AE (non-RX Drug)

      Serious adverse event(s) for a non-prescription drug used in the United States has not been reported to the Secretary.

    3. Data secured in course of each test

      Laboratory records do not include a complete record of all data secured in the course of each test, including all graphs and spectra from laboratory instrumentation, properly identified to show the specific component and in-process material.

    4. 21 CFR 11

      Electronic records

      Electronic records are used, but they do not meet system access limitation , audit trail and signature to record linking requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.

    5. Late submission

      Each post marketing 15-day Alert report was not submitted to FDA within 15 calendar days of initial receipt of the information.

  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Unapproved and Misbranded DrugsCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Calibration/Inspection/Checking not done

      Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

    2. Written program not followed

      The written stability testing program is not followed.

    3. Control procedures fail to include the following

      Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity.

    4. Procedures are written, and followed

      Procedures designed to assure that correct labeling and packaging materials are used for drug products are not followed.

    5. Test methods

      The sensitivity of test methods have not been documented.

    Show 1 more citation
    1. Following/documenting laboratory controls

      Established laboratory control mechanisms are not documented at the time of performance.

  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Control procedures fail to include the following

      Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity.

    2. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    3. Acceptance criteria for sampling & testing

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release.

    4. Handling and Storage to Prevent Contamination

      There was a failure to handle and store components at all times in a manner to prevent contamination.

    5. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.

    Show 2 more citations
    1. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    2. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    3. Suitability of testing methods verified

      The suitability of all testing methods is not verified under actual conditions of use.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    5. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals in accordance with an established written program.

    Show 2 more citations
    1. Unauthorized Personnel in Limited Access Areas

      Unauthorized personnel have access to enter areas of the buildings and facilities designated as limited access areas.

    2. Inadequate number of personnel

      The number of qualified personnel is inadequate to supervise the manufacture, processing, packing, and holding of each drug product.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Dec 22, 2025. It asked for a Form 483.

  • Inspection ending Sep 19, 2025VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 on Feb 2, 2026. FDAgent holds no copy that FDA posted.

    1. Dec 22, 2025FDA-FOIA-2025-14293Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 17 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 8 inspections, with how many of them cited each.

Show all 17

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1019820, one row per refused product line.

1 refusal on 2017-06-09 · charged UNAPPROVED on 1 · no FDA sample analysis

FDA firm profile
  • 2017-06-09

    TRIAMCINOLONE ACETONIDE (GLUCOCORTICOID)64LCJ61

    UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG

    Division of Southeast Imports799-0787779-6/11/1

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling
Registration runs through
Dec 31, 2027
Registrant
Crown LaboratoriesD-U-N-S 079035945

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1019820 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1019820. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.