Skip to content

Bora Pharmaceuticals Injectables Inc

CT STATE ZIP CODE. COUNTRY TPE ESTABISAENT NEPECTED, Maryland, USA

FEI 1000512361DUNS 119352788

FDA has 16 inspections on file for Bora Pharmaceuticals Injectables Inc in Maryland (FEI 1000512361), from 2009 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Two of the nine FOIA requests for this site have asked FDA for this inspection's 483.

The most recent OAI inspection ended on Feb 18, 2022. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations I). No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2026. Its registrant is Bora Pharmaceuticals Injectables Inc. (D-U-N-S 119352788).

Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
16, 2009–2026
1 OAI · 11 VAI · 3 NAI
Inspections with 483 observations shown
7 of 16
Form 483s posted by FDA
↗
Requested under FOIA
9 requests, latest Jun 2, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

16 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate investigations of contamination

      OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A) Your firm failed to thoroughly investigate Out of Limit (OOS) investigations that were initiated in response to personnel monitoring samples that exceeded the specifications for the controlled classified spaces, specifically Grade A and Grade B, which are utilized to produce sterile drug products. The corrective and preventative actions instituted did not address the root cause of the persistent personnel monitoring recoveries to mitigate sterile drug product quality impact. There were approximately 189 personnel monitoring Out of Limit (OOL) investigations from 06/2023-03/2026; 80 of the investigations describe isolates that were classified as objectionable microorganisms. The following are some examples of the investigations which have inadequate corrective and preventative actions: Investigation No. Initiation Date Sterile Drug Product Summary Batch Deviation- 02/09/2024 (b)(4) Recover 04/05/2024 008745 ed gram negative objectionable lot #(b)(4) - organism Moraxella osloensis during personnel monitoring following exit from syringe filling line in room #(b)(4). Deviation- 01/04/2024 (b)(4) Recover 06/05/2024 008549 ed gram negative objectionable Injection, lot #(b)(4) - organism Moraxella osloensis during personnel monitoring. Deviation- 03/04/2024 (b)(4) Recover 08/01/2024 008968 ed gram negative objectionable lot #(b)(4) - organism Paracoccus yeei during personnel monitoring following exit from syringe filling line in room #(b)(4). Deviation- 03/04/2024 (b)(4) Recover 08/07/2024 008969 ed gram negative objectionable lot #(b)(4) - organism Roseomonas mucosa during personnel monitoring following exit from syringe filling line in room #(b)(4). Deviation- 06/11/2024 (b)(4) Recover 10/31/2024 009444 ed gram negative objectionable Injection, lot #(b)(4). Deviation- 07/05/2024 (b)(4) Recover 09/03/2024 009556 ed gram negative objectionable lot #(b)(4) - organism Acinetobacter ursingii during personnel monitoring following exit from vial filling line in room #(b)(4). (Additional similar investigation entries omitted here due to repetitive footer interruptions in the record.) B) The procedure that delineates analytical and microbiology laboratory out of specification investigations is SOP017591 and is titled "Out-of-Specification (OOS) Results: Preliminary Assessment and OOS Investigation." According to the procedure, sterility failure test invalidation must follow the guidelines of USP <71>. Hence, a sterility test may be invalidated if the growth of the identified species "may be ascribed unequivocally to faults with respect to the material and or the technique used in conducting the sterility test." However, the following investigations that were initiated in response to (b)(4) lots that resulted in sterility test positives, were attributed to a laboratory microbiologist error, without definitively ruling out the possibility that the sterile drug products were contaminated during production. The following sterility test failure investigations did not have scientifically sound root cause assessments: Isolated (investigation entries with redactions) 001M/DEV- lot hominis 010511 (b)(4) , lot #(b)(4). 002M/DEV- luteus and 010514 (b)(4), lot #(b)(4), Staphylococcus (entries contain redactions). C) The quality unit released sterile drug products without conducting a scientifically sound assessment of how critical defects, such as human hair contamination found during visual inspection of finished products, would impact the quality, safety, and purity of the products. Furthermore, there is no assurance that these lots are free from additional particulate matter. For example: During the initial 100% Visual Inspection of (b)(4) (b)(4) Injection, Batch #(b)(4), (b)(4) vials were identified to contain visible particles. During Level 1 evaluation, 135 of the units were confirmed to contain

      Shortened here; the PDF has the full text.

    2. Observation 2

      Cleaning procedures not followed

      OBSERVATION 2 Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, The facility procedure and work instruction that describes the cleaning and disinfecting of controlled classified spaces (i.e., Grade A-Grade D) are titled "Baltimore (BPII) Production Facility Cleaning" and "Baltimore (BPII) Production Facility Cleaning Work Instruction," respectively. The firm produces sterile drug products in the facility controlled classified areas. The aseptic core facility cleaning is performed on a (b)(4) and (b)(4) basis. The procedure indicates for equipment, (b)(4) surfaces, and (b)(4) to be wiped with (b)(4) following a (b)(4) disinfectant (i.e., (b)(4) and (b)(4) Solution) contact time; however, it is not effective in removing the disinfectant residue. During the walkthrough on 03/12/2024, we observed apparent disinfectant residue on the (b)(4) panels that encompasses the (b)(4) Vial Filler (Equipment ID # (b)(4)), (b)(4) and a (b)(4) table located in the controlled classified areas.

    Show observation 3
    1. Observation 3

      Aseptic processing and airflow deficiencies

      OBSERVATION 3 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. The following deficiencies in aseptic processing were identified through observation of the (b)(4) filling suite operations (filling line setup/assembly on March 16, 2026 and filling operations on March 18, 2026) and review of smoke study videos for the (b)(4) syringe filling suite, (b)(4) vial filling suite, (b)(4), (b)(4), (b)(4) Aseptic Storage: i. Aseptic operators failed to follow standard procedures for good aseptic practices, as evidenced by the following observations: a. Operators did not adhere to the principle of slow and deliberate movement required in aseptic environments. Specifically, on March 18, 2026, operators were observed walking rapidly through narrow passages between the room wall and sections of the (b)(4) in the area where the vial turntable and stopper bowl are located. This rapid movement can generate air turbulence, creating a risk of Grade B air ingress into the (b)(4) through gaps between panels and potentially compromising the Grade A environment inside the (b)(4). b. Operators were observed removing vials from the vial transfer turntable on March 18, 2026 while blocking first air over the vials with a (b)(4). This is also evidenced in smoke study video footage titled "Dynamic (Operating) Filling." ii. Review of the smoke study video for the syringe filling line in the aseptic filling suite (Room (b)(4)) revealed the following aseptic technique deficiencies: (1) operators' (b)(4) hands contacted direct product-contact components of the (b)(4) pumps and indirect product-contact components of the stopper delivery system and stoppering station during aseptic assembly and setup; (2) operators' (b)(4) hands obstructed first air over the direct and indirect product-contact surfaces of these components; (3) operators manipulated filling needles and syringe tubs containing exposed syringes with (b)(4) hands; and (4) operators obstructed first air over stoppers in the stopper bowl with a non-sterile stopper bag. iii. The video footage titled "Dynamic (Operations) (b)(4)" shows that during aseptic assembly of the sterile receiving vessel in the (b)(4) filling suite, operators' (b)(4) hands obstructed first air over exposed direct product-contact surfaces of the following components: receiving vessel tubing assembly, (b)(4), (b)(4), and connecting tubing. iv. The video footage titled "Dynamic (Operations) Filler Setup Part 1" and "Dynamic (interventions) Filling Stoppering Part 1" show that during aseptic assembly of the filling stations and filling nozzle realignment in the (b)(4) filling suite, the operators were observed touching the nozzle and nozzle holding brackets. In addition, operators' (b)(4) hands obstructed first air over exposed direct product-contact surfaces of the filling nozzles. v. The video footage titled "(b)(4)", "(b)(4)", and "Dynamic (Operating) Filling" shows that during loading and unloading of the HEPA (High-Efficiency Particulate Air) filters, the operator's head and upper torso were in close proximity to (b)(4) vials in the trays, thereby obstructing first air over the vials. vi. The video footage titled "(b)(4) Dynamic" shows that during unloading of depyrogenated vials in the sterile storage suite (b)(4), the operators' (b)(4) hands contacted the exterior surface of the (b)(4) boxes that contain the depyrogenated vials. B. Your firm's qualification of airflow in the aseptic filling suite (room (b)(4)), RPT063352 (version 1.0, approved May 12, 2023) is deficient. i. The airflow visualization study (smoke study) failed to meet acceptance criteria for unidirectional, turbulence-free airflow. Specifically, the airflow to the critical aseptic processing areas inside the (b)(4) is provided by (b)(4) HEPA filters. An approximately (b)(4) gap exists between the ceiling and the upper section of the (b)(4). Smoke st

      Shortened here; the PDF has the full text.

  2. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written records kept in individual logs

      Written records of major equipment use are not included in individual equipment logs.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    3. Rejecting When Specifications Not Met

      Failure to reject any lot of components, drug product containers and closures that did not meet the appropriate written specifications for identity, strength, quality, and purity.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  8. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Second person sign off

      Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.

  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Control procedures to monitor and validate performance

      Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    2. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

  11. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

  12. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not justified.

  13. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  14. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Vaccines and Allergenic ProductsCitations not published
  15. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  16. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Nine requests to FDA under the Freedom of Information Act named this site, most recently on Jun 2, 2026. Each one asked for a Form 483.

  • Inspection ending Mar 20, 2026Not classified yet

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jun 2, 2026FDA-FOIA-2026-5476Form 483Records released
    2. May 8, 2026FDA-FOIA-2026-4743Form 483· 1 of 5 sitesRecords released
  • Inspection ending Aug 10, 2023VAI

    3 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Aug 12, 2024FDA-FOIA-2024-7161Form 483· 1 of 5 sitesClosed
    2. Aug 8, 2024FDA-FOIA-2024-7109Form 483· 1 of 5 sitesClosed
    3. Oct 6, 2023FDA-FOIA-2023-8776Form 483Closed
  • Inspection ending Feb 18, 2022OAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jun 29, 2026. FDAgent holds no copy that FDA posted.

    1. Jun 2, 2026FDA-FOIA-2026-5473Form 483· 1 of 5 sitesRecords released
    2. Sep 20, 2022FDA-FOIA-2022-6729Form 483Closed
  • Inspection ending Feb 17, 2022

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Oct 24, 2023FDA-FOIA-2023-9389Form 483Closed
  • Inspection ending Apr 16, 2021VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Apr 1, 2022FDA-FOIA-2022-2418Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 6 of this facility’s 16 inspections, with how many of them cited each.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2026
Registrant
Bora Pharmaceuticals Injectables Inc.D-U-N-S 119352788

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000512361 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000512361. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.