Bora Pharmaceuticals Injectables Inc Form 483, March 2026
FDA issued this Form 483 to Bora Pharmaceuticals Injectables Inc in Maryland (FEI 1000512361) at the end of an inspection that ran from March 12 to March 20, 2026. It lists 3 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Jul 10, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection
- Mar 12–20, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Jul 10, 2026
- 112 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate investigations of contamination
OBSERVATION 1 There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. Specifically, A) Your firm failed to thoroughly investigate Out of Limit (OOS) investigations that were initiated in response to personnel monitoring samples that exceeded the specifications for the controlled classified spaces, specifically Grade A and Grade B, which are utilized to produce sterile drug products. The corrective and preventative actions instituted did not address the root cause of the persistent personnel monitoring recoveries to mitigate sterile drug product quality impact. There were approximately 189 personnel monitoring Out of Limit (OOL) investigations from 06/2023-03/2026; 80 of the investigations describe isolates that were classified as objectionable microorganisms. The following are some examples of the investigations which have inadequate corrective and preventative actions: Investigation No. Initiation Date Sterile Drug Product Summary Batch Deviation- 02/09/2024 (b)(4) Recover 04/05/2024 008745 ed gram negative objectionable lot #(b)(4) - organism Moraxella osloensis during personnel monitoring following exit from syringe filling line in room #(b)(4). Deviation- 01/04/2024 (b)(4) Recover 06/05/2024 008549 ed gram negative objectionable Injection, lot #(b)(4) - organism Moraxella osloensis during personnel monitoring. Deviation- 03/04/2024 (b)(4) Recover 08/01/2024 008968 ed gram negative objectionable lot #(b)(4) - organism Paracoccus yeei during personnel monitoring following exit from syringe filling line in room #(b)(4). Deviation- 03/04/2024 (b)(4) Recover 08/07/2024 008969 ed gram negative objectionable lot #(b)(4) - organism Roseomonas mucosa during personnel monitoring following exit from syringe filling line in room #(b)(4). Deviation- 06/11/2024 (b)(4) Recover 10/31/2024 009444 ed gram negative objectionable Injection, lot #(b)(4). Deviation- 07/05/2024 (b)(4) Recover 09/03/2024 009556 ed gram negative objectionable lot #(b)(4) - organism Acinetobacter ursingii during personnel monitoring following exit from vial filling line in room #(b)(4). (Additional similar investigation entries omitted here due to repetitive footer interruptions in the record.) B) The procedure that delineates analytical and microbiology laboratory out of specification investigations is SOP017591 and is titled "Out-of-Specification (OOS) Results: Preliminary Assessment and OOS Investigation." According to the procedure, sterility failure test invalidation must follow the guidelines of USP <71>. Hence, a sterility test may be invalidated if the growth of the identified species "may be ascribed unequivocally to faults with respect to the material and or the technique used in conducting the sterility test." However, the following investigations that were initiated in response to (b)(4) lots that resulted in sterility test positives, were attributed to a laboratory microbiologist error, without definitively ruling out the possibility that the sterile drug products were contaminated during production. The following sterility test failure investigations did not have scientifically sound root cause assessments: Isolated (investigation entries with redactions) 001M/DEV- lot hominis 010511 (b)(4) , lot #(b)(4). 002M/DEV- luteus and 010514 (b)(4), lot #(b)(4), Staphylococcus (entries contain redactions). C) The quality unit released sterile drug products without conducting a scientifically sound assessment of how critical defects, such as human hair contamination found during visual inspection of finished products, would impact the quality, safety, and purity of the products. Furthermore, there is no assurance that these lots are free from additional particulate matter. For example: During the initial 100% Visual Inspection of (b)(4) (b)(4) Injection, Batch #(b)(4), (b)(4) vials were identified to contain visible particles. During Level 1 evaluation, 135 of the units were confirmed to contain
Shortened here; the PDF has the full text.
- 2
Cleaning procedures not followed
OBSERVATION 2 Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, The facility procedure and work instruction that describes the cleaning and disinfecting of controlled classified spaces (i.e., Grade A-Grade D) are titled "Baltimore (BPII) Production Facility Cleaning" and "Baltimore (BPII) Production Facility Cleaning Work Instruction," respectively. The firm produces sterile drug products in the facility controlled classified areas. The aseptic core facility cleaning is performed on a (b)(4) and (b)(4) basis. The procedure indicates for equipment, (b)(4) surfaces, and (b)(4) to be wiped with (b)(4) following a (b)(4) disinfectant (i.e., (b)(4) and (b)(4) Solution) contact time; however, it is not effective in removing the disinfectant residue. During the walkthrough on 03/12/2024, we observed apparent disinfectant residue on the (b)(4) panels that encompasses the (b)(4) Vial Filler (Equipment ID # (b)(4)), (b)(4) and a (b)(4) table located in the controlled classified areas.
- 3
Aseptic processing and airflow deficiencies
OBSERVATION 3 Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. Specifically, A. The following deficiencies in aseptic processing were identified through observation of the (b)(4) filling suite operations (filling line setup/assembly on March 16, 2026 and filling operations on March 18, 2026) and review of smoke study videos for the (b)(4) syringe filling suite, (b)(4) vial filling suite, (b)(4), (b)(4), (b)(4) Aseptic Storage: i. Aseptic operators failed to follow standard procedures for good aseptic practices, as evidenced by the following observations: a. Operators did not adhere to the principle of slow and deliberate movement required in aseptic environments. Specifically, on March 18, 2026, operators were observed walking rapidly through narrow passages between the room wall and sections of the (b)(4) in the area where the vial turntable and stopper bowl are located. This rapid movement can generate air turbulence, creating a risk of Grade B air ingress into the (b)(4) through gaps between panels and potentially compromising the Grade A environment inside the (b)(4). b. Operators were observed removing vials from the vial transfer turntable on March 18, 2026 while blocking first air over the vials with a (b)(4). This is also evidenced in smoke study video footage titled "Dynamic (Operating) Filling." ii. Review of the smoke study video for the syringe filling line in the aseptic filling suite (Room (b)(4)) revealed the following aseptic technique deficiencies: (1) operators' (b)(4) hands contacted direct product-contact components of the (b)(4) pumps and indirect product-contact components of the stopper delivery system and stoppering station during aseptic assembly and setup; (2) operators' (b)(4) hands obstructed first air over the direct and indirect product-contact surfaces of these components; (3) operators manipulated filling needles and syringe tubs containing exposed syringes with (b)(4) hands; and (4) operators obstructed first air over stoppers in the stopper bowl with a non-sterile stopper bag. iii. The video footage titled "Dynamic (Operations) (b)(4)" shows that during aseptic assembly of the sterile receiving vessel in the (b)(4) filling suite, operators' (b)(4) hands obstructed first air over exposed direct product-contact surfaces of the following components: receiving vessel tubing assembly, (b)(4), (b)(4), and connecting tubing. iv. The video footage titled "Dynamic (Operations) Filler Setup Part 1" and "Dynamic (interventions) Filling Stoppering Part 1" show that during aseptic assembly of the filling stations and filling nozzle realignment in the (b)(4) filling suite, the operators were observed touching the nozzle and nozzle holding brackets. In addition, operators' (b)(4) hands obstructed first air over exposed direct product-contact surfaces of the filling nozzles. v. The video footage titled "(b)(4)", "(b)(4)", and "Dynamic (Operating) Filling" shows that during loading and unloading of the HEPA (High-Efficiency Particulate Air) filters, the operator's head and upper torso were in close proximity to (b)(4) vials in the trays, thereby obstructing first air over the vials. vi. The video footage titled "(b)(4) Dynamic" shows that during unloading of depyrogenated vials in the sterile storage suite (b)(4), the operators' (b)(4) hands contacted the exterior surface of the (b)(4) boxes that contain the depyrogenated vials. B. Your firm's qualification of airflow in the aseptic filling suite (room (b)(4)), RPT063352 (version 1.0, approved May 12, 2023) is deficient. i. The airflow visualization study (smoke study) failed to meet acceptance criteria for unidirectional, turbulence-free airflow. Specifically, the airflow to the critical aseptic processing areas inside the (b)(4) is provided by (b)(4) HEPA filters. An approximately (b)(4) gap exists between the ceiling and the upper section of the (b)(4). Smoke st
Shortened here; the PDF has the full text.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.