Sage Pharmaceuticals, Inc.
5408 Interstate Dr, Shreveport, Louisiana, United States
FEI 1000112409
FDA has 3 inspections on file for Sage Pharmaceuticals, Inc. in Shreveport, Louisiana (FEI 1000112409), from 2009 to 2012. The latest ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2009–2012
- 1 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Unapproved and Misbranded Drugs7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Show 2 more citations
Control procedures fail to include the following
Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Unapproved and Misbranded Drugs13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices.
Control procedures fail to include the following
Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity.
Calibration - at intervals, written program, remedial action
The calibration of instruments and apparatus is not done at suitable intervals in accordance with an established written program.
Failing drug products not rejected
Drug products failing to meet established specifications are not rejected.
Show 8 more citations
Variation in the Amount of Components Used
The master production and control records are deficient in that they lack a justification for the variation in the amount of components used in the preparation of a dosage form.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Reporting of adverse drug experience to FDA
Written procedures describing the handling of all written and oral complaints do not include provisions for review to determine whether the complaint represents a serious and unexpected adverse drug experience which is required to be reported to the Food and Drug Administration.
Specific information required in individual logs
Individual equipment logs do not show time, date, product, and lot number of each batch processed.
Equipment for Environmental Control
Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Testing and standardization of standards et. al.
Laboratory records do not include complete records of any testing and standardization of laboratory reference standards, reagents, and standard solutions.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications2 of 2
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 2
- 21 CFR 211.142Warehousing procedures2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.111Time limitations on production1 of 2
Show all 14
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.194Laboratory records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000112409 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000112409. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.