Alcami Carolinas Corporation
4221 Faber Place Dr, Charleston, South Carolina, United States
FEI 1000110990DUNS 832394733
Company: Alcami Carolinas Corporation · Linked by exact D-U-N-S match (831351445) in FDA registration data
FDA has 11 inspections on file for Alcami Carolinas Corporation in Charleston, South Carolina (FEI 1000110990), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the seven FOIA requests for this site has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.160(a) and 21 CFR 211.192.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2026. Its registrant, Alcami Carolinas Corporation (D-U-N-S 831351445), has registered 9 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 11, 2009–2026
- 0 OAI · 6 VAI · 5 NAI
- Inspections with 483 observations shown
- 3 of 11
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 7 requests, latest Oct 7, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
11 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesPosted 483 · 7 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Training , Education , Experience overall
Employees engaged in the processing of a drug product lack the training required to perform their assigned functions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Lab controls established, including changes
The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
Show 2 more citations
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and instructions for removal or obliteration of previous batch identification.
Investigations of discrepancies, failures
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
In-process materials characteristics testing
In-process materials are not tested for quality and approved or rejected by the quality control unit during the production process.
Show 1 more citation
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Following/documenting laboratory controls
Established specifications and test procedures are not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on Oct 7, 2026.
Inspection ending Apr 22, 2026VAI
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 16, 2026FDA-FOIA-2026-6766Form 483Records released
Inspection ending Jan 29, 2026
1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Feb 27, 2026. FDAgent holds no copy that FDA posted.
- Feb 25, 2026FDA-FOIA-2026-1956Form 483Records released
Inspection ending Apr 5, 2024VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 4, 2024FDA-FOIA-2024-8799Form 483Closed
- May 6, 2024FDA-FOIA-2024-4143Form 483· 1 of 3 sitesClosed
Inspection ending Oct 29, 2021VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 4, 2024FDA-FOIA-2024-8797Form 483Closed
Inspection ending Dec 15, 2017VAI
1 request. In the inspection history above. FDA released records in answer to a request for its Inspection records on Oct 29, 2026. FDAgent holds no copy that FDA posted.
- Oct 7, 2026FDA-FOIA-2026-9737Inspection recordsRecords released
Inspection date not given
1 request.
- Jan 29, 2019FDA-FOIA-2019-250Form 483 + EIROpen
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 11 inspections, with how many of them cited each.
- 21 CFR 211.160General requirements2 of 3
- 21 CFR 211.192Production record review2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.25Personnel qualifications1 of 3
- 21 CFR 211.42Design and construction features1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
Show all 11
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.194Laboratory records1 of 3
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, analysis
- Registration runs through
- Dec 31, 2026
- Registrant
- Alcami Carolinas CorporationD-U-N-S 831351445
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Alcami Carolinas Corporation (D-U-N-S 831351445) as the registrant for this site and the 9 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Alcami Carolinas CorporationMorrisville, North Carolina · FEI 10001585825 inspections5latestAug 11, 2026VAINone on file
- Alcami Carolinas CorporationWilmington, North Carolina · FEI 104941813 inspections13latestSep 26, 2025VAINone on file
- Alcami Carolinas CorporationSaint Louis, Missouri · FEI 19420947 inspections7latestOct 4, 2024VAINone on file
- Alcami Carolinas CorporationPepperell, Massachusetts · FEI 3002940424Registered; no FDA inspection on file
- Alcami Carolinas CorporationReno, Nevada · FEI 3010163990Registered; no FDA inspection on file
- Alcami Carolinas CorporationCharleston, South Carolina · FEI 3023245328Registered; no FDA inspection on file
- Alcami Carolinas CorporationShirley, Massachusetts · FEI 3030362524Registered; no FDA inspection on file
- Alcami Carolinas CorporationAmherst, New Hampshire · FEI 3030362525Registered; no FDA inspection on file
- Alcami Carolinas CorporationGarner, North Carolina · FEI 3030396596Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 1000110990 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 1000110990. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.