21 CFR 212.50: What production and process controls must I have?
FDA's inspection data lists 60 Form 483 citations of 21 CFR 212.50 at 49 facilities, from January 2013 to August 21, 2026. 1 warning letter states a violation of it.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 60
- At 54 inspections
- Facilities cited
- 49
- Distinct FEIs
- Most recent citation
- Aug 21, 2026
- Pharmalogic Puerto Rico Inc
- Warning letters
- 1
- State a violation of it
The regulation
The current text of 21 CFR 212.50 from the Electronic Code of Federal Regulations.
§ 212.50 What production and process controls must I have?
You must have adequate production and process controls to ensure the consistent production of a PET drug that meets the applicable standards of identity, strength, quality, and purity.
(a) Written control procedures. You must have written production and process control procedures to ensure and document that all key process parameters are controlled and that any deviations from the procedures are justified.
(b) Master production and control records. You must have master production and control records that document all steps in the PET drug production process. The master production and control records must include the following information:
(1) The name and strength of the PET drug;
(2) If applicable, the name and radioactivity or other measurement of each active pharmaceutical ingredient and each inactive ingredient per batch or per unit of radioactivity or other measurement of the drug product, and a statement of the total radioactivity or other measurement of any dosage unit;
(3) A complete list of components designated by names and codes sufficiently specific to indicate any special quality characteristic;
(4) Identification of all major pieces of equipment used in production;
(5) An accurate statement of the weight or measurement of each component, using the same weight system (metric, avoirdupois, or apothecary) for each component. Reasonable variations are permitted in the amount of component necessary if they are specified in the master production and control records;
(6) A statement of action limits on radiochemical yield, i.e., the minimum percentage of yield beyond which investigation and corrective action are required;
(7) Complete production and control instructions, sampling and testing procedures, specifications, special notations, and precautions to be followed; and
(8) A description of the PET drug product containers, closures, and packaging materials, including a specimen or copy of each label and all other labeling.
(c) Batch production and control records. Each time a batch of a PET drug is produced, a unique batch production and control record must be created. The batch production record must include the following information:
(1) Name and strength of the PET drug;
(2) Identification number or other unique identifier of the specific batch that was produced;
(3) The name and radioactivity or other measure of each active pharmaceutical ingredient and each inactive ingredient per batch or per unit of radioactivity or other measurement of the drug product;
(4) Each major production step (obtained from the approved appropriate master production and control record);
(5) Weights (or other measure of quantity) and identification codes of components;
(6) Dates of production steps and times of critical production steps;
(7) Identification of major pieces of equipment used in production of the batch;
(8) Testing results;
(9) Labeling;
(10) Initials or signatures of persons performing or checking each significant step in the operation; and
(11) Results of any investigations conducted.
(d) Area and equipment checks. The production area and all equipment in the production area must be checked to ensure cleanliness and suitability immediately before use. A record of these checks must be kept.
(e) In-process materials controls. Process controls must include control of in-process materials to ensure that the materials are controlled until required tests or other verification activities have been completed or necessary approvals are received and documented.
(f) Process verification. (1) For a PET drug for which each entire batch undergoes full finished-product testing to ensure that the product meets all specifications, process verification, as described in paragraph (f)(2) of this section, is not required.
(2) When the results of the production of an entire batch of a PET drug are not fully verified through finished-product testing or when only the initial sub-batch in a series is tested, the PET drug producer must demonstrate that the process for producing the PET drug is reproducible and is capable of producing a drug product that meets the predetermined acceptance criteria. Process verification activities and results must be documented. Documentation must include the date and signature of the individual(s) performing the verification, the monitoring and control methods and data, and the major equipment qualified.
21 CFR Part 212: Current Good Manufacturing Practice for Positron Emission Tomography Drugs, Subpart FRead on eCFR
Citations by year
Form 483 citations of 21 CFR 212.50 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 15 in 2025
| Year | Form 483 citations |
|---|---|
| 2013 | 2 |
| 2014 | 1 |
| 2015 | 3 |
| 2016 | 4 |
| 2017 | 3 |
| 2018 | 5 |
| 2019 | 4 |
| 2020 | 2 |
| 2021 | 2 |
| 2022 | 1 |
| 2023 | 3 |
| 2024 | 3 |
| 2025 | 15 |
| 2026 | 12 |
How FDA words this citation
FDA's short descriptions and citation text on these 60 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Adequate controls (general)34 citations
- Written control procedures7 citations
- Complete instructions, procedures, specs4 citations
- Production area & equipment checks3 citations
- ID of major equipment2 citations
Show 3 more
- Master Production and Control Records2 citations
- Results of investigations2 citations
- Action limits on radiochemical yield1 citations
Citation text
- “Your firm lacks adequate production and process controls to ensure the consistent production of a PET drug that meets the applicable standards of identity, strength, quality and purity.”34 citations
- “You did not have master production and control records that document all steps in the PET drug production process.”2 citations
- “You did not have written production and process control procedures to ensure that all key process parameters are controlled.”2 citations
- “You did not have written production and process control procedures to ensure that any deviations from the procedures are justified.”2 citations
Show 2 more
- “Your batch production and control records did not include the results of any investigations conducted.”2 citations
- “Your batch production record did not include the identification of major pieces of equipment used in production of the batch.”2 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 212.50, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- Mayo Clinic PET Radiochemistry Facility2026-07-17 · FEI 3014201471Complete instructions, procedures, specs
Show 4 more
- University Of Texas MD Anderson Cancer Center: PET2026-02-24 · FEI 3008927689Adequate controls (general)
- Biomedical Research Foundation of Northwest Louisiana2026-02-20 · FEI 3023494155Adequate controls (general)
What the observations say
Excerpts from Form 483s that FDA posted in its reading room. A Form 483 usually doesn't name the regulation, so FDAgent ties an observation to 21 CFR 212.50 only when it opens with one of FDA's standard citation texts for this section, word for word apart from case, spacing and punctuation. 4 observations tie this way. The highlighted sentence is the matched wording.
PETNET Solutions Inc.2026-05-22 · Observation 3
Your master production and control records did not include a statement of action limits on radiochemical yield. Specifically, A. The manufacturing batch records for (b) (4) Injection do not include action limits on radiochemical yield. For example, Manufacturing batch record for PPQ batch # (b) (4) on page 3 of 26 Section, Final Product Vial Assay and Sterility Inoculations, the radiochemical yield is only recorded, however, there is no …
This observation opens with FDA's standard wording for 21 CFR 212.50(b)(6).
Isorx Cyclotron Center2026-03-13 · Observation 5
You did not have written production and process control procedures to ensure that any deviations from the procedures are justified. Specifically, 2026-0217-1 - CAPA still open with outstanding work not completed and no additional comments of status or when it will be completed. Doc 131 Inventory Management SOP was supposed to be finalized by the end of February. As of this inspection it has not be completed and the CAPA has not been updated with …
This observation opens with FDA's standard wording for 21 CFR 212.50(a).
PETNET Solutions, Inc.2026-03-06 · Observation 1
Your firm lacks adequate production and process controls to ensure the consistent production of a PET drug that meets the applicable standards of identity, strength, quality and purity. Specifically, A. Test procedures for performing bacterial endotoxin testing lack adequate instruction to prevent variability in sample handling that could produce inconsistent test results. For example, on 03/05/2026: o the operator performing quality control …
This observation opens with FDA's standard wording for 21 CFR 212.50.
Show 1 more
PETNET Solutions Inc2026-02-17 · Observation 3
Your process controls did not include control of in-process materials to ensure that the materials are controlled until required tests or other verification activities have been completed or necessary approvals are received and documented. Specifically, you do not have an in-process check on the (b) (4) target material for radioactive content. This material is returned to you as reprocessed product from all your domestic sites for re-use in your …
This observation opens with FDA's standard wording for 21 CFR 212.50(e).
Warning letters stating a violation of 21 CFR 212.50
1 warning letter FDA posted states a violation of this section in a numbered violation sentence. The most recent are below, each linking to FDAgent's page for the letter.
“Your firm failed to have adequate production and process controls to ensure the consistent production of a PET drug that meets the applicable standards of identity, strength, quality, and purity (21 CFR 212.50).”
- 3D Imaging Drug Design and Development LLCIssued 2025-12-04
Often cited at the same inspection
Of the 54 inspections where FDA cited 21 CFR 212.50, the share where it also cited each of these sections.
- 21 CFR 212.20What activities must I perform to ensure drug quality?34 (63%)
- 21 CFR 212.30What requirements must my facilities and equipment meet?28 (52%)
- 21 CFR 212.60What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?15 (28%)
- 21 CFR 212.40How must I control the components I use to produce PET drugs and the containers and closures I package them in?12 (22%)
- 21 CFR 212.70What controls and acceptance criteria must I have for my finished PET drug products?5 (9%)
- 21 CFR 212.71What actions must I take if a batch of PET drug product does not conform to specifications?4 (7%)
Ask FDAgent about 21 CFR 212.50
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 212.50; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.