21 CFR 212.70: What controls and acceptance criteria must I have for my finished PET drug products?
FDA's inspection data lists 13 Form 483 citations of 21 CFR 212.70 at 12 facilities, from October 2015 to September 19, 2025.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 13
- At 13 inspections
- Facilities cited
- 12
- Distinct FEIs
- Most recent citation
- Sep 19, 2025
- Barbara Ann Karmanos Cancer Hospital
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 212.70 from the Electronic Code of Federal Regulations.
§ 212.70 What controls and acceptance criteria must I have for my finished PET drug products?
(a) Specifications. You must establish specifications for each PET drug product, including criteria for determining identity, strength, quality, purity, and, if appropriate, sterility and pyrogens.
(b) Test procedures. Before you implement a new test procedure in a specification, you must establish and document the accuracy, sensitivity, specificity, and reproducibility of the procedure. If you use an established compendial test procedure in a specification, you must first verify and document that the test works under the conditions of actual use.
(c) Conformance to specifications. Before final release, you must conduct an appropriate laboratory determination to ensure that each batch of a PET drug product conforms to specifications, except for sterility. For a PET drug product produced in sub-batches, before final release, you must conduct an appropriate laboratory determination to ensure that each sub-batch conforms to specifications, except for sterility.
(d) Final release procedures. Except as conditional final release is permitted in accordance with paragraph (f) of this section, you must establish and follow procedures to ensure that each batch of a PET drug product is not given final release until the following are done:
(1) An appropriate laboratory determination under paragraph (c) of this section is completed;
(2) Associated laboratory data and documentation are reviewed and they demonstrate that the PET drug product meets specifications, except for sterility; and
(3) A designated qualified individual authorizes final release by dated signature.
(e) Sterility testing. Sterility testing need not be completed before final release but must be started within 30 hours after completion of production. The 30-hour requirement may be exceeded due to a weekend or holiday. If the sample for sterility testing is held longer than 30 hours, you must demonstrate that the longer period does not adversely affect the sample and the test results obtained will be equivalent to test results that would have been obtained if the test had been started within the 30-hour time period. Tested samples must be from individual batches and not pooled. If the product fails to meet a criterion for sterility, you must immediately notify all facilities that received the product of the test results and provide any appropriate recommendations. The notification must be documented. Upon completion of an investigation into the failure to meet a criterion for sterility, you must notify all facilities that received the product of the findings from the investigation.
(f) Conditional final release. (1) If you cannot complete one of the required finished-product tests for a batch of a PET drug product because of a malfunction involving analytical equipment, you may approve the conditional final release of the product if you meet the following conditions:
(i) You have data documenting that preceding consecutive batches, produced using the same methods used for the conditionally released batch, demonstrate that the conditionally released batch will likely meet the established specifications;
(ii) You determine that all other acceptance criteria are met;
(iii) You retain a reserve sample of the conditionally released batch of drug product;
(iv) You promptly correct the malfunction of analytical equipment, complete the omitted test using the reserve sample after the malfunction is corrected, and document that reasonable efforts have been made to prevent recurrence of the malfunction;
(v) If you obtain an out-of-specification result when testing the reserve sample, you immediately notify the receiving facility; and
(vi) You document all actions regarding the conditional final release of the drug product, including the justification for the release, all followup actions, results of completed testing, all notifications, and corrective actions to prevent recurrence of the malfunction involving analytical equipment.
(2) Even if the criteria in paragraph (f)(1) of this section are met, you may not approve the conditional final release of the product if the malfunction involving analytical equipment prevents the performance of a radiochemical identity/purity test or prevents the determination of the product's specific activity.
(3) You may not release another batch of the PET drug product until you have corrected the problem concerning the malfunction of analytical equipment and completed the omitted finished-product test.
21 CFR Part 212: Current Good Manufacturing Practice for Positron Emission Tomography Drugs, Subpart HRead on eCFR
Citations by year
Form 483 citations of 21 CFR 212.70 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 5 in 2025
| Year | Form 483 citations |
|---|---|
| 2015 | 2 |
| 2016 | 1 |
| 2018 | 1 |
| 2019 | 2 |
| 2020 | 1 |
| 2023 | 1 |
| 2025 | 5 |
How FDA words this citation
FDA's short descriptions and citation text on these 13 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Conform to specs prior to release5 citations
- When 30 hour rule is exceeded2 citations
- Before implementing new procedure establish and document accuracy etc.1 citations
- Compendial test procedure1 citations
- Correct malfunction, re-do test1 citations
Show 3 more
- Data and documentation review1 citations
- Final dated signature1 citations
- Sub-batches1 citations
Citation text
- “You did not conduct an appropriate laboratory determination to ensure that each batch of a PET drug product conforms to specifications before final release.”4 citations
- “A sample for sterility testing was held longer than 30 hours, but you did not demonstrate that the longer period did not adversely affect the sample and that the test results obtained were equivalent to test results that would have been obtained if the test had been started within the 30 hour period.”2 citations
- “You approved a conditional final release of a PET drug product batch due to analytical equipment malfunction, but you did not document that reasonable efforts had been made to prevent recurrence of the malfunction.”1 citations
- “You did not conduct an appropriate laboratory determination on a PET drug produced in sub-batches before final release to ensure that each sub-batch conformed to specifications.”1 citations
Show 2 more
- “You did not conduct an appropriate laboratory determination to ensure that each batch of a PET drug conforms to specifications before final release.”1 citations
- “You did not establish procedures to ensure that each batch or sub-batch of a PET drug product was not given final release until associated laboratory data and documentation were reviewed and PET drug products were demonstrated to meet specifications.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 212.70, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
- SOFIE Co. dba SOFIE2023-01-20 · FEI 3005705951Before implementing new procedure establish and document accuracy etc.
Show 4 more
Often cited at the same inspection
Of the 13 inspections where FDA cited 21 CFR 212.70, the share where it also cited each of these sections.
- 21 CFR 212.20What activities must I perform to ensure drug quality?8 (62%)
- 21 CFR 212.30What requirements must my facilities and equipment meet?5 (38%)
- 21 CFR 212.50What production and process controls must I have?5 (38%)
- 21 CFR 212.60What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?4 (31%)
- 21 CFR 212.10What personnel and resources must I have?3 (23%)
- 21 CFR 212.71What actions must I take if a batch of PET drug product does not conform to specifications?3 (23%)
Ask FDAgent about 21 CFR 212.70
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 212.70; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.