Skip to content

UCSF Radiopharmaceutical Facility

185 Berry St Ste 350, San Francisco, California, United States

FEI 3005947301DUNS 831727388

FDA has 3 inspections on file for UCSF Radiopharmaceutical Facility in San Francisco, California (FEI 3005947301), from 2015 to 2025. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 4 citations from this inspection, all under 21 CFR Part 212, the manufacturing rules for PET drugs. They are listed below. Four FOIA requests have asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for PET drug production, through Dec 31, 2026. Its registrant is UCSF Radiopharmaceutical Facility (D-U-N-S 831727388).

Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2015–2025
1 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 3
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
4 requests, latest May 14, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written QA procedures established, followed

      You did not follow written quality assurance procedures.

    2. Adequate controls (general)

      Your firm lacks adequate production and process controls to ensure the consistent production of a PET drug that meets the applicable standards of identity, strength, quality and purity.

    3. Conform to specs prior to release

      You did not conduct an appropriate laboratory determination to ensure that each batch of a PET drug product conforms to specifications before final release.

    4. Written control procedures

      You did not have written production and process control procedures to ensure that all key process parameters are controlled.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Lab written procedures

      Laboratory written procedures are not established to ensure that the lab equipment is routinely calibrated and maintained.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Four requests to FDA under the Freedom of Information Act named this site, most recently on May 14, 2026. Each one asked for a Form 483.

  • Inspection ending Jul 24, 2025OAI

    4 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 23, 2025. FDAgent holds no copy that FDA posted.

    1. May 14, 2026FDA-FOIA-2026-4944Form 483· 1 of 5 sitesWithdrawn
    2. Mar 23, 2026FDA-FOIA-2026-2855Form 483Records released
    3. Nov 13, 2025FDA-FOIA-2025-12923Form 483Records released
    4. Aug 26, 2025FDA-FOIA-2025-10177Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 4 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

  • 21 CFR 212.20What activities must I perform to ensure drug quality?1 of 2
  • 21 CFR 212.50What production and process controls must I have?1 of 2
  • 21 CFR 212.60What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?1 of 2
  • 21 CFR 212.70What controls and acceptance criteria must I have for my finished PET drug products?1 of 2

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDA drug establishment registration

FDA registration search
Registered operations
PET drug production
Registration runs through
Dec 31, 2026
Registrant
UCSF Radiopharmaceutical FacilityD-U-N-S 831727388

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005947301 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005947301. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.