Pharmalogic Puerto Rico Inc
150 Calle Federico Costa, San Juan, Puerto Rico, United States
FEI 3009288779DUNS 832856756
Company: Pharmalogic Holdings Corp. · Linked by exact D-U-N-S match (079711874) in FDA registration data
FDA has 4 inspections on file for Pharmalogic Puerto Rico Inc in San Juan, Puerto Rico (FEI 3009288779), from 2013 to 2026. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 5 citations from this inspection, all under 21 CFR Part 212, the manufacturing rules for PET drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for PET drug production, through Dec 31, 2026. Its registrant, Pharmalogic Holdings Corp. (D-U-N-S 079711874), has registered 13 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2013–2026
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Oct 22, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Supplies adequately controlled
Your identity, purity and quality of supplies used in your testing procedures are not adequately controlled.
Equipment procedures
You did not implement procedures to ensure that all equipment is properly installed, maintained, and capable of repeatedly producing valid results that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained.
Written control procedures
You did not have written production and process control procedures to ensure and document that all key process parameters are controlled.
Determination need for investigation
When errors occurred or a production batch or any component of the batch, failed to meet specifications, you did not determine the need for an investigation, conduct an investigation and take appropriate corrective actions when necessary.
Use of reliable suppliers
You did not use a reliable supplier as a source of each lot of component and container.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Correct malfunction, re-do test
You approved a conditional final release of a PET drug product batch due to analytical equipment malfunction, but you did not document that reasonable efforts had been made to prevent recurrence of the malfunction.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Oct 22, 2026. Each one asked for a Form 483.
Inspection ending Aug 21, 2026VAI
1 request. In the inspection history above.
- Oct 22, 2026FDA-FOIA-2026-10253Form 483· 1 of 5 sitesOpen
Inspection date not given
1 request. None of FDA’s log entries for these requests say records were released.
- Nov 16, 2023FDA-FOIA-2023-10276Form 483 + EIRClosed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 6 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 212.20What activities must I perform to ensure drug quality?1 of 2
- 21 CFR 212.30What requirements must my facilities and equipment meet?1 of 2
- 21 CFR 212.40How must I control the components I use to produce PET drugs and the containers and closures I package them in?1 of 2
- 21 CFR 212.50What production and process controls must I have?1 of 2
- 21 CFR 212.60What requirements apply to the laboratories where I test components, in-process materials, and finished PET drug products?1 of 2
- 21 CFR 212.70What controls and acceptance criteria must I have for my finished PET drug products?1 of 2
FDA drug establishment registration
FDA registration search- Registered operations
- PET drug production
- Registration runs through
- Dec 31, 2026
- Registrant
- Pharmalogic Holdings Corp.D-U-N-S 079711874
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Pharmalogic Holdings Corp. (D-U-N-S 079711874) as the registrant for this site and 13 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Precision Nuclear, LLCJohnson City, Tennessee · FEI 30056842753 inspections3latestSep 17, 2026VAINone on file
- Essential Isotopes, LLCColumbia, Missouri · FEI 30064777514 inspections4latestSep 11, 2026VAINone on file
- Pharmalogic New York City, LLCBronx, New York · FEI 30295146241 inspection1latestAug 19, 2026OAINone on file
- Pharmalogic Salt Lake City, LLCSalt Lake City, Utah · FEI 30294974441 inspection1latestFeb 24, 2026VAINone on file
- Pharmalogic Los Angeles, LLCLos Angeles, California · FEI 30297783111 inspection1latestFeb 5, 2026VAINone on file
- Wisconsin Medical Radiopharmacy, LLCWest Allis, Wisconsin · FEI 30046372252 inspections2latestNov 20, 2025NAINone on file
- Pharmalogic Cincinatti, LLCCincinnati, Ohio · FEI 30289881821 inspection1latestOct 24, 2025NAINone on file
- Precision Nuclear of Virginia, LLCSalem, Virginia · FEI 30065185113 inspections3latestOct 17, 2025VAINone on file
- Pharmalogic South Carolina, LLCDuncan, South Carolina · FEI 30053917595 inspections5latestJul 10, 2025NAINone on file
- Pharmalogic Colorado, LLCAurora, Colorado · FEI 30174536741 inspection1latestNov 12, 2021NAINone on file
- Hot Shots Nm, LLCDavenport, Iowa · FEI 30079394972 inspections2latestAug 9, 2019VAINone on file
- Pharmalogic Austin, LLCAustin, Texas · FEI 3029262794Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3009288779 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3009288779. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.