FDA issued this Form 483 to US Specialty Formulations LLC in Allentown, Pennsylvania (FEI 3010680515) at the end of a drug inspection that ended April 26, 2022. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on July 26, 2023.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Sep 26, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 26, 2022
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Sep 26, 2022
153 days after the inspection
Facility
FEI 3010680515
Allentown, Pennsylvania

FDA's 16 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Air Supply

    Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.

  2. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.

  3. Buildings of Suitable Size, Construction, Location

    Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

  4. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  5. Following/documenting laboratory controls

    Established laboratory control mechanisms are not followed.

  6. Protection from external factors

    Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.

  7. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

  8. Valid stability test methods

    The written stability program for drug products does not include meaningful and specific test methods.

  9. Determination of conformance

    Determinations of conformance to appropriate written specifications for acceptance are deficient in that they are not made for each lot within each shipment of components used in the manufacture, processing, packing or holding of drug products.

  10. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the sterilization process.

  11. Microbiological testing

    Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

  12. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  13. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.

  14. Calibration/Inspection/Checking not done

    Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.

  15. Protective Apparel Not Worn

    Protective apparel is not worn as necessary to protect drug products from contamination.

  16. FDCA 503B(a)(10)

    Drug product label, outsourcer facility

    The labels of your outsourcing facility's drug products are deficient.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3010680515, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.