Skip to content

Teva Parenteral Medicines, Inc. Form 483, July 2009

FDA issued this Form 483 to Teva Parenteral Medicines, Inc. in Irvine, California (FEI 2027158) at the end of a drug inspection that ended July 24, 2009. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 24, 2009
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
5,290 days after the inspection
Facility
FEI 2027158
Irvine, California

FDA's 16 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Extent of discrepancy, failure investigations

    Investigations of an unexplained discrepancy did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

  2. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

  3. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  4. Acceptance criteria for sampling & testing

    Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet appropriate statistical quality control criteria as a condition for their approval and release.

  5. Procedures not in writing, fully followed

    The responsibilities and procedures applicable to the quality control unit are not in writing.

  6. Approve or reject procedures or specs

    The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.

  7. Objectionable microbiological contamination

    Each lot of a component liable to objectionable microbiological contamination is deficiently subjected to microbiological tests before use.

  8. Microbiological testing

    Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

  9. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

  10. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

  11. In-process materials characteristics testing

    In-process materials are not tested for quality and purity and approved or rejected by the quality control unit during the production process.

  12. Equipment Design, Size and Location

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

  13. Cleaning / Sanitizing / Maintenance

    Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  14. Quality control unit review of records

    Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

  15. Equipment to control conditions

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

  16. Cleaning/maintenance records not kept

    Records are not kept for the cleaning and sanitizing of equipment.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterDec 11, 2009CDER · 140 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 2027158, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.