Skip to content

Tailor Made Compounding, LLC Form 483, October 2018

FDA issued this Form 483 to Tailor Made Compounding, LLC in Nicholasville, Kentucky (FEI 3012315020) at the end of a drug inspection that ended October 24, 2018. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Feb 21, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Oct 24, 2018
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Feb 21, 2020
485 days after the inspection
Facility
FEI 3012315020
Nicholasville, Kentucky

FDA's 12 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  2. Equipment to control conditions

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

  3. Extent of discrepancy, failure investigations

    Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.

  4. Calibration/Inspection/Checking not done

    Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

  5. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  6. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

  7. Component identity verification

    Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.

  8. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

  9. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  10. Examination of issued labels

    Labeling materials issued for a batch were not carefully examined for identity and conformity to the labeling specified in the master or batch production records.

  11. Establishment of time limitations

    Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

  12. Protective Apparel Not Worn

    Protective apparel is not worn as necessary to protect drug products from contamination.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterApr 1, 2020CDER · 525 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3012315020, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.