Skip to content

Pacifico National, Inc. dba AmEx Pharmacy Form 483, May 2019

FDA issued this Form 483 to Pacifico National, Inc. dba AmEx Pharmacy in Melbourne, Florida (FEI 3012034698) at the end of a drug inspection that ended May 31, 2019. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jul 9, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
May 31, 2019
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jul 9, 2019
39 days after the inspection
Facility
FEI 3012034698
Melbourne, Florida

FDA's 13 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Strict control not exercised over labeling issued

    Strict control is not exercised over labeling issued for use in drug product labeling operations.

  2. Reports of Analysis (Components)

    Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

  3. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  4. Training , Education , Experience overall

    Employees engaged in the manufacture, processing and packing of a drug product lack the education, training and experience required to perform their assigned functions.

  5. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

  6. Protective Apparel Not Worn

    Protective apparel is not worn as necessary to protect drug products from contamination.

  7. Test methods

    The accuracy, sensitivity, specificity and reproducibility of test methods have not been established.

  8. Results not used for expiration dates, storage cond.

    Results of stability testing are not used in determining expiration dates.

  9. Establishment of time limitations

    Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

  10. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the aseptic and sterilization process.

  11. Complaint Handling Procedure

    Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

  12. Reserve sample retention time

    The retention period for drug product reserve samples (except those described in 211.170(b)(2) and (3)) is deficient in that they are not retained for one year after the expiration date of the drug product.

  13. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3012034698, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.