Pacifico National, Inc. dba AmEx Pharmacy
1515 Elizabeth St Ste J, Melbourne, Florida, United States
FEI 3012034698
FDA has 2 inspections on file for Pacifico National, Inc. dba AmEx Pharmacy in Melbourne, Florida (FEI 3012034698), from 2016 to 2019. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2016–2019
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 2
- 1 posted 483 not matched to an inspection
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 13 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Training , Education , Experience overall
Employees engaged in the manufacture, processing and packing of a drug product lack the education, training and experience required to perform their assigned functions.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Show 8 more citations
Protective Apparel Not Worn
Protective apparel is not worn as necessary to protect drug products from contamination.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established.
Results not used for expiration dates, storage cond.
Results of stability testing are not used in determining expiration dates.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the aseptic and sterilization process.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Reserve sample retention time
The retention period for drug product reserve samples (except those described in 211.170(b)(2) and (3)) is deficient in that they are not retained for one year after the expiration date of the drug product.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality Assurance11 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate media fill program
1. Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed. Specifically, A. The media fills performed to qualify technicians in aseptic re-packaging operations of Avastin syringes were not adequate in that only (B)(&) was required to qualify a technician in aseptic operations as per SOP TR 1.5 Media Fill. However, according to the Pharmacist-in-Charge/Quality Assurance and the Process Organizational Chart-Sterile Compounding, (B){#) technicians are qualified to perform aseptic re-packaging of Avastin with a maximum of {(5){) which was not demonstrated during their media fills and therefore, the media fills were not representative of the current process. Upon review of media fill documentation the following deficiencies were found: a) None of the “qualified” aseptic technicians had adequate documentation of (6) (2) that represents worst-case conditions, i.e. (B)&) / cleanroom, breaks, gowning/re-gowning, fatigue, etc. that would provide a challenge to aseptic operations. The QA Manager also stated that media fills are not observed by a qualified person to assess aseptic technique and behavior. b) The documentation for the media fill performed by aseptic technician (©) on (B)#) showed (P©) only re-packaged (B)(&) but ®6 is currently allowed to re-package (6) (&). B@ were sampled for microbiological contamination, no environmental monitoring (gown, air, and surface) was conducted, and the time duration of the media fill was not documented. The media fill check boxes "Pass" or "Fail" were not checked, but the media fill was approved by QA on (B)(&). c) The documentation for the media fill performed by aseptic technician (#6) on (B){&) did not record the number of units filled, incubated, or found positive. There was no environmental monitoring (gown, air, and surface) and the time duration of the media fill was not documented. However, this media fill was approved by QA on (B)IE. d) The documentation for the media fill performed by aseptic technician (86) on (B)& as "Initial Testing" did not document the number of units filled, incubated, or found positive. There was no environmental monitoring for gown and surface. The media fill check boxes "Pass" or "Fail" were not checked, but the media fill was approved by QA on (B)@). e) The documentation for the media fill performed by aseptic technician B16 on (B)# as "ongoing testing" did not record the number of units filled, incubated, or found positive. It only records (b) (&). The fingertip sampling section was crossed out and environmental sampling for gown, air, and surface was not conducted. However, this media fill was checked as "Pass" and was approved by QA on (B)@). f) The documentation for the media fill performed by aseptic technician 1 on (B)# only documented (5) (&) but B1@ is qualified to fill up to (5) &). There was no environmental sampling (gown, air and surface), but the media fill was checked as "Pass" and it was approved by QA on (B){#). g) The documentation for the media fill performed by aseptic technician BJ on (BJZ) only documented 81, but is qualified to fill up to (6). There was no environmental sampling (gown, air and surface), but the media fill was checked as "Pass" and it was approved by QA on (BJ&)]. h) The documentation for the media fill performed by aseptic technician (B){8) on (E){& only documented (®)#) (6) (2), but ¥8 is qualified to fill up to (B)(&). There was no environmental sampling (gown, air and surface), but the media fill was checked as "Pass" and it was approved by QA on (B){). i) The documentation for the media fill performed by aseptic technician (8) on (B)(&) only documented © (b) (4), but ®9 is qualified to fill up to (B)(&). There was no environmental sampling (gown, air and surface), but the media fill was checked as "Pass" and it was approved by QA on (B)(&). j) The documentation for the media fill performed by aseptic technician (B){8) on (B)@
Shortened here; the PDF has the full text.
- Observation 2
Cleaning/disinfecting procedures deficient
2. Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, A. The suitability, efficacy, and limitations of disinfecting agents and procedures have not been assessed and approved to ensure potential contaminants are adequately removed from surfaces in the ISO 5 & 7 classified areas. For example, a) According to Policy CS 1: Control of Systems and Procedures for Maintaining Facilities approved by QA on 9/23/15 and Job Aid CS 1.4: Cleaning and Disinfecting Procedures, the firm uses (8)(4) (b) (4), Sterile (B)(&) ®@ and (6) however, it was found the following cleaning agents were discontinued or replaced with a different agent within the last few months (no specific date) as follows: 1) B@ - no longer used as it was not sterile. 2) B® - no longer used as it was not sterile. 3) B@ - replaced by (B)(@) to be used (H@). 4) (B)@" - replaced by (B)) to be used (B)(&). There was no documentation for the assessment and approval of any of these cleaning agents and written procedures for their preparation, required contact time, and rotational schedule were not established. In addition, cleanroom cleaning records reviewed from September 2015 through present did not document the (b) (4) cleaning agent used and the reason for (6). B. Upon observation of cleaning activities and environmental monitoring prior to re-packaging Avastin (BZ) lot #(B)(@) performed by aseptic technician (B)) on 1/15/16, we noted the following deficiencies: a) The technician wiped and disinfected the surfaces of only half of the (6)(z) ISO 5 Laminar Airflow Workbench (LAFW) prior to performing aseptic operations. The (E)(&) LAFW is not (5) and (B)@) ) thus increasing the potential for dust particulates from the unwiped side to be introduced into the aseptic work area. This practice of cleaning and sanitizing half of the LAFW surfaces is not in accordance with your SOP CS 1.4 "Cleaning and Disinfecting Procedures." b) The technician placed the settle plate for viable particulate monitoring on the (B){#) 1 away from the aseptic work area and blocked by an approximately 6” high plastic bin. This location for air monitoring was not representative of the aseptic work area. SOP EP 1.3 "Air Sampling- Settle plate sampling" states ® @®@ . B)@ but does not provide additional guidance or precautions to ensure air sampling is representative of the aseptic work area.
Show observations 3 to 11
- Observation 3
Air supply/cleanroom qualification deficiencies
3. Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, a) The latest two (2) qualifications of the (B){#)] ISO 7 cleanroom # (B)() and the (B){&) ISO 5 hoods completed on BE) by a contractor do not document if qualifications were performed under static or dynamic conditions with maximum number of personnel. In addition, smoke studies were performed and recorded with (CIZENOIA) which does not represent current practice of up to ™* (5) {#) in cleanroom ®&. b) The firm lacked calibration records for the magnehelic gauges that measure differential pressure in the cleanrooms. There are no written procedures for the calibration of these gauges.
- Observation 4
Failed OOS procedure/inadequate investigations
4. Your firm failed to establish and follow an Out of Specification (OOS) Procedure. As a result, your quality unit failed to conduct investigations when the following non-sterile results were received from your contract testing laboratories (CTLs). a) On 1/26/15, your firm received a non-sterile (evidence of growth) result from your CTL for Lot # 150122C (batch size of (B)@). Your quality unit failed to request a laboratory investigation from the CTL and failed to conduct a root cause investigation. Instead, your quality unit shipped additional samples to a secondary CTL and those results were reported on 2/12/15 as sterile. Without invalidating the previous non-sterile results with a sound and scientific rationale, your quality unit released and shipped on 2/17/15 and 2/18/15 8 patient-specific repackaged Avastin syringes from Lot # 150122C to multiple doctors offices. b) On 1/23/15, your firm received a non-sterile (evidence of growth) result from your CTL for Lot # 1501201 (batch size of ##). Your quality unit failed to request a laboratory investigation from the CTL and failed to conduct a root cause investigation. Instead, your quality unit shipped additional samples to a secondary CTL and those results were reported on 2/2/15 as sterile. Without invalidating the previous non-sterile results with a sound and scientific rationale, your quality unit released and shipped on 2/17/15 and 2/18/15 B/@ patient-specific repackaged Avastin syringes from Lot # 150120] to multiple doctors offices. c) On 12/29/14, prior to receiving the sterility test results, your quality unit released and shipped Lot # 141224C (batch size (B)(@) 1 patient-specific repackaged Avastin syringes to a doctor’s office. On 1/19/15, your quality unit received an email from your CTL stating a non-sterile result. The CTL investigation stated that it was not a laboratory error. Your quality unit failed to conduct a root cause investigation and instead conducted a recall on 1/20/15 and received a total of [illegible] repackaged Avastin syringes back (no documentation of the return). A total of 8 patient-specific repackaged Avastin syringes were administered to patients. Your quality unit failed to follow up with the patients and instead submitted the additional samples to the CTL for re-testing. On 2/16/15, your firm received a sterile result from the CTL. d) On 9/17/15, prior to receiving the sterility test results, and without the quality unit's approval your firm shipped Lot # 150915B (batch size of #1) patient-specific repackaged Avastin syringes to a doctor’s office. On 9/30/15, your quality unit received an email from your CTL stating a non-sterile result. The CTL investigation stated that it was not a laboratory error. Your quality unit failed to conduct a root cause investigation and instead conducted a recall on 10/7/15. A total of ®® patient-specific repackaged Avastin syringes were administered to patients. Your quality unit failed to follow up with the patients. e) On 3/19/15 and 3/23/15, prior to receiving the sterility test results, your quality unit released and shipped Lot # 1503 16H (batch size of ()#@) patient-specific repackaged Avastin syringes to multiple doctors’ offices. On 4/7/15, your quality unit received an email from your CTL stating a non-sterile result. The CTL investigation stated that it was not a laboratory error. Your quality unit failed to conduct a root cause investigation and instead conducted a recall on 4/7/15 and received a total of ®@ repackaged Avastin syringes back (no documentation of the return). A total of #4 patient-specific repackaged Avastin syringes were administered to patients. Your quality unit failed to follow up with the patients. f) Lot # 150119R (batch size of (B){#) made on 1/19/15 and Lot 150116B (batch size of) made on 01/16/15 were released and shipped prior to receiving the sterility test results. Both lots were reported to be non-sterile by the CTL. For both lots, your quality unit failed to conduc
Shortened here; the PDF has the full text.
- Observation 5
Complaint handling not followed
5. Procedures for handling complaints were not followed. Specifically, your firm failed to follow Job Aid QS 2.2: “How to Document and Report a Patient Complaint” (job aid was never approved by the Quality Unit) as it states to research the root cause of the complaint as necessary and record the results of the investigation. In addition, your firm failed to provide instructions within the Job Aid on how to report complaints that represent serious and unexpected adverse drug experiences to the FDA. Your firm failed to investigate the following unexpected adverse drug experiences: a) In July 2015, your firm received a complaint for Lot # 150710A regarding two patients experiencing blurry vision after being administered the repackaged Avastin injection by the doctor. On 3/26/15, your firm received a complaint from a doctor’s office regarding two patients experiencing eye infections after being administered the repackaged Avastin injections. Your quality unit failed to conduct investigations for these product complaints. In addition, your firm cannot trace a specific lot back to a particular patient. Instead, your firm can only trace which lots were shipped to the doctor’s office. The doctor received the following lots 150129H, 1501291 and 150129Q, but it is unclear which lot was administered to the two patients that were affected. b) Since registering as a 503(b) facility on 9/21/15 your firm has received 68 consumer complaints relating to the plunger not advancing, fibers found on the needle, etc. These complaints have never been reviewed or investigated by the quality unit. Your firm’s current practice for receiving complaints is through the Customer Service Representatives (CSRs) whose sole responsibility is replacing the implicated syringes. The CSRs then forward the complaints via email to the Quality Assurance Manager and Pharmacist in Charge. It was observed during the inspection that both the QA Manager and Pharmacist in Charge had consumer complaints within their emails for which they had not reviewed or investigated, one of which being the adverse drug experience regarding the eye infections received on 3/26/15. The Pharmacist in Charge stated the complaint files have not been adequately maintained and at the completion of monthly Continuous Quality Improvement Meetings these records are discarded. c) Since 1/5/15 your firm has received a total of 917 consumer complaints (for which only replacement syringes were sent to the doctors’ offices) relating to a cloudy syringe, plunger not advancing, fibers found on the needles, under-filling of the repackaged Avastin, etc. Your firm has been aware of the complaint issues regarding the plunger not advancing since the 2009 (5) (%) Study which attributed the root cause as (5) (&). Your firm has still not taken the appropriate corrective and preventative actions to address the issue. Since 1/5/15, your firm has received a total of 363 consumer complaints for the plunger not advancing. These complaints have never been reviewed or investigated by the quality unit.
- Observation 6
Stability data not used for BUDs
6. Results of stability testing are not used in determining expiration dates. Specifically, your outsourcing facility lacked valid analytical and sterility data to support the 90-day beyond use date (BUD) assigned to repackaged syringes of preservative-free Avastin (Bevacizumab) (6) &). According to your firm's Pharmacist in Charge/QA, the BUD was based on three (3) articles published in scientific journals. However, this information is not specific to your firm's operations. As per Job Aid SE 1: “Stability and Beyond Use Dating,” your firm has ongoing stability studies of {8) 4).
- Observation 7
Quality unit roles not defined/followed
7. Procedures describing the role and responsibilities of the quality control unit have not been adequately established and followed. Specifically, the Pharmacist-in-Charge/QA and the Quality Assurance Manager were uncertain about their duties and responsibilities regarding complaint handling, deviation investigations, adverse event investigation and reporting, documentation practices, adherence to written procedures, batch record and label review, cleaning procedures, personnel training, and performance of adequate media fills among other duties.
- Observation 8
Incomplete batch records/yield not documented
8. Batch records for re-packaged Avastin do not provide complete documentation of production of each batch of drug product. The actual batch yield is not documented and compared to the theoretical yield. As a result, your outsourcing facility was unable to maintain accurate accountability of syringes filled for each batch.
- Observation 9
Unable to trace batch to patient
9. Your outsourcing facility was unable to identify which batch of Avastin was dispensed to each patient due to specimens of patient-specific labels not being maintained within the batch record.
- Observation 10
Labels missing required 503B information
10. The labels of your outsourcing facility’s drug products do not include information required by section 503B(a)(10)(A)&(B). Specifically, the following information is not found on your drug product labels: a) The statements “This is a compounded drug” and “Not for resale”. Examples of drug product labels that do not contain this information: * Buprenorphine HCL (Grape) 8 mg Troche * Linaclotide 75Smcg/ml suspension * Imiquimod/Deoxy-D-Glucose/EGCG/Salicyclic Acid 5%/1%/1%/10% Cream * Metronidazole/Oxymetazoline/Niacinamide 1%/0.075%/4% Cream * Minoxidil/Salicylic Acid 5%/2% Solution b) The date that the drug was compounded, storage and handling instructions, and list of active and inactive ingredients are not found on your product labels. Examples of drug products labels that do not contain this information: * Buprenorphine HCL (Grape) 8 mg Troche * Linaclotide 75mcg/ml suspension * Imiquimod/Deoxy-D-Glucose/EGCG/Salicyclic Acid 5%/1%/1%/10% Cream * Metronidazole/Oxymetazoline/Niacinamide 1%/0.075%/4% Cream * Minoxidil/Salicylic Acid 5%/2% Solution c) Furthermore, the following information is not found on the container labels for the drug products you produce: Information to facilitate adverse event reporting: www.fda.gov/medwatch and 1-800-FDA-1088. Examples of container labels that do not contain this information: * Buprenorphine HCL (Grape) 8 mg Troche * Linaclotide 75mcg/m] suspension * Imiquimod/Deoxy-D-Glucose/EGCG/Salicyclic Acid 5%/1%/1%/10% Cream * Metronidazole/Oxymetazoline/Niacinamide 1%/0.075%/4% Cream * Minoxidil/Salicylic Acid 5%/2% Solution
- Observation 11
Failure to report products to FDA
11. Your outsourcing facility did not submit a product report to FDA identifying a product compounded during the previous six months prior to registration on 9/21/15 as required by section 503B(b)(2)(A). Specifically, the following products were compounded or repackaged between 3/21/15 and 9/21/15 but were not identified on your report dated 12/4/2015: a) Avastin 1.25 mg/Dexamethasone 800mcg injectable b) Methacholine Inhalation Solution c) Non-sterile compounded drug products include but are not limited to: * Buprenorphine HCL (Grape) 8 mg Troche * Linaclotide 75mcg/ml suspension * Imiquimod/Deoxy-D-Glucose/EGCG/Salicyclic Acid 5%/1%/1%/10% Cream * Metronidazole/Oxymetazoline/Niacinamide 1%/0.075%/4% Cream
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.28Personnel responsibilities1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.111Time limitations on production1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
Show all 11
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.170Reserve samples1 of 1
- 21 CFR 211.198Complaint files1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012034698 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012034698. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.