Skip to content

LCC Ltd. Form 483, March 2024

FDA issued this Form 483 to LCC Ltd. in Eumseong, Korea (the Republic of) (FEI 3007255059) at the end of a drug inspection that ended March 22, 2024. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on November 22, 2024.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 20, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Mar 22, 2024
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Oct 20, 2026
942 days after the inspection
Facility
FEI 3007255059
Eumseong, Korea (the Republic of)

FDA's 11 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Testing Each Component for Conformity with Specs

    Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

  2. Scientifically sound laboratory controls

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.

  3. Supervisor Training/Education/Experience

    Individuals responsible for supervising the manufacture, processing, packing and holding of a drug product lack the education, training and experience to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.

  4. Approve or reject procedures or specs

    The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality and purity of drug products.

  5. Complaint Investigation/Follow-Up Findings

    Complaint records are deficient in that they do not include the findings of the investigation and follow-up.

  6. Cleaning SOPs/instructions

    Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.

  7. Equipment Design, Size and Location

    Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use and cleaning and maintenance.

  8. Records not made readily available to FDA

    Records associated with drug product components, production, control and distribution and within the retention period for such records, were not made readily available for authorized inspection.

  9. Prepared for each batch, include complete information

    Batch production and control records do not include complete information relating to the production and control of each batch.

  10. Expiration date lacking

    Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

  11. Control procedures to monitor and validate performance

    Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.