Lantheus Medical Imaging, Inc. Form 483, April 2026

FDA issued this Form 483 to Lantheus Medical Imaging, Inc. in North Billerica, Massachusetts (FEI 1216602) at the end of a drug inspection that ended April 9, 2026. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Oct 23, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Apr 9, 2026
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Oct 23, 2026
197 days after the inspection
Facility
FEI 1216602
North Billerica, Massachusetts

FDA's 7 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Computer control of master formula records

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

  2. Label storage access limited to authorized personnel

    Access to the storage area for labels and labeling materials is not limited to authorized personnel.

  3. Investigations of discrepancies, failures

    There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  4. Strict control not exercised over labeling issued

    Strict control is not exercised over labeling issued for use in drug product labeling operations.

  5. Component written specification

    Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

  6. Scientifically sound laboratory controls

    Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that components and drug product containers conform to appropriate standards of identity, strength, quality and purity.

  7. Procedures not in writing, fully followed

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.