Skip to content

Kalman Health & Wellness, Inc. dba Essential Wellness Pharma Form 483, July 2015

FDA issued this Form 483 to Kalman Health & Wellness, Inc. dba Essential Wellness Pharma in Peoria, Illinois (FEI 3011581046) at the end of a drug inspection that ended July 21, 2015. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 21, 2015
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,102 days after the inspection
Facility
FEI 3011581046
Peoria, Illinois

FDA's 14 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Prepared for each batch, include complete information

    Batch production and control records do not include complete information relating to the production and control of each batch.

  2. Cleaning / Sanitizing / Maintenance

    Equipment and utensils are not cleaned, maintained, and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

  3. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  4. Protective Apparel Not Worn

    Protective apparel is not worn as necessary to protect drug products from contamination.

  5. Calibration/Inspection/Checking not done

    Routine calibration of equipment is not performed according to a written program designed to assure proper performance.

  6. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.

  7. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

  8. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

  9. Retest of approved components/containers/closures

    Approved components and closures are not retested or reexamined as appropriate for identity, strength, quality and purity after exposure to conditions that might have an adverse effect with subsequent approval or rejection by the quality control unit.

  10. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  11. Testing Each Component for Conformity with Specs

    Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

  12. Defined areas of adequate size for operations

    The separate or defined areas necessary to prevent contamination or mix-ups are deficient.

  13. Microbiological Contamination Exam

    Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

  14. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterJul 25, 2016CDER · 370 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3011581046, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.