Skip to content

International Laboratories Corp Form 483, September 2024

FDA issued this Form 483 to International Laboratories Corp in Bang Phli, Thailand (FEI 3006403166) at the end of a drug inspection that ended September 20, 2024. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on March 10, 2025.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Sep 20, 2024
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Nov 17, 2026
788 days after the inspection
Facility
FEI 3006403166
Bang Phli, Thailand

FDA's 7 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Scientifically sound laboratory controls

    Laboratory controls do not include the establishment of scientifically sound and appropriate designed to assure that conform to appropriate standards of identity, strength, quality and purity.

  2. Samples (various types) representative, identified properly

    Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of components are not representative.

  3. Computer control of master formula records

    Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

  4. Complete test data included in records

    Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

  5. Procedures not in writing, fully followed

    The responsibilities and procedures applicable to the quality control unit are not in writing.

  6. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  7. Absence of Written Procedures

    Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.