Central Admixture Pharmacy Services, Inc. Form 483, July 2023

FDA issued this Form 483 to Central Admixture Pharmacy Services, Inc. in Phoenix, Arizona (FEI 3014307835) at the end of a drug inspection that ended July 31, 2023. FDA classified the inspection Official Action Indicated (OAI) and issued the facility a warning letter on March 25, 2024.

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 15, 2023. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jul 31, 2023
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Nov 15, 2023
107 days after the inspection
Facility
FEI 3014307835
Phoenix, Arizona

FDA's 17 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  2. Sanitation--buildings not clean, free of infestation

    Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds insects, and other vermin.

  3. Drug products - samples representative, identified properly

    Samples taken of drug products for determination of conformance to written specifications are not properly identified.

  4. Procedures not in writing, fully followed

    The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

  5. Procedures are written, and followed

    Procedures designed to assure that correct labels are used for drug products are not followed.

  6. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

  7. Results not used for expiration dates, storage cond.

    Results of stability testing are not used in determining expiration dates.

  8. Prepared for each batch, include complete information

    Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.

  9. Test methods

    The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.

  10. Equipment to control conditions

    Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

  11. input/output verification

    Input to and output from the computer, related systems of formulas and records or data are not checked for accuracy.

  12. Failure to submit ADE report

    Adverse drug experience information has not been reported to FDA.

  13. Absence of Written Procedures

    Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

  14. Calibration - at intervals, written program, remedial action

    The calibration of instruments, apparatus and recording devices is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.

  15. Procedures for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

  16. SOPs not followed / documented

    Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

  17. Quality control unit review of records

    Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3014307835, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.