Tacoma-Pierce County Blood Bank
220 S I St, Tacoma, Washington, United States
FEI 3075335
FDA has 8 inspections on file for Tacoma-Pierce County Blood Bank in Tacoma, Washington (FEI 3075335), from 2009 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 2 citations from this inspection: 1 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 1 under 21 CFR Part 606, the manufacturing rules for blood and blood components. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 606.100(b) and 21 CFR 606.100(c).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2009–2023
- 0 OAI · 3 VAI · 5 NAI
- Inspections with 483 observations shown
- 4 of 8
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written calibration / inspection records not kept
Records of the of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Equipment observed, standardized, calibrated
Equipment used in the collection, processing and storage and distribution of blood and blood components is not calibrated on a regularly scheduled basis as prescribed in the SOP Manual.
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the processing of blood and blood components for allogeneic transfusion were not always followed.
Provide space for quarantine of unsuitable for use items
Failure to provide adequate space for the quarantine and disposition of products and reagents not suitable for use.
Thorough investigations
Failure to perform a thorough investigation of a failure of a lot or unit to meet any of its specifications.
Equipment calibration frequency
Equipment used in the processing of blood and blood components is not observed, standardized and calibrated with at least the frequency required.
CPR certification
Failure to assure that an individual who is currently certified in cardiopulmonary resuscitation is located on the premises whenever collections of blood or blood components are performed.
Show 1 more citation
Required records
Failure to maintain general records.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Following manufacturer's instructions
Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and storage of blood and blood components for homologous transfusion and further manufacturing purposes are not always followed.
Thorough investigations
Failure to perform a thorough investigation of an unexplained discrepancy.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection of blood and blood components for homologous transfusion are not always followed.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 606.100Standard operating procedures3 of 4
- 21 CFR 606.60Equipment2 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 4
- 21 CFR 606.40Facilities1 of 4
- 21 CFR 606.65Supplies and reagents1 of 4
- 21 CFR 606.160Records1 of 4
- 21 CFR 630.5Medical supervision1 of 4
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3075335 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3075335. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.