Wells Pharma of Houston LLC
Houst on, Texas, United States
FEI 3016710931DUNS 055774114
FDA has 4 inspections on file for Wells Pharma of Houston LLC in Houst on, Texas (FEI 3016710931), from 2021 to 2026. The latest ended on ; FDA has not posted its classification yet.
FDA posted the Form 483 from that inspection. FDAgent read its 6 observations from the PDF; they are listed below. One FOIA request has asked FDA for this inspection's 483.
The most recent OAI inspection ended on Mar 28, 2025. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.113(b) and 21 CFR 211.22(d).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for repacking, through Dec 31, 2027. Its registrant is Wells Pharma of Houston, LLC (D-U-N-S 055774114).
Sources:FDA firm profile ↗Form 483 PDF ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- Inspections on file
- 4, 2021–2026
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- Requested under FOIA
- 1 request, latest Jul 13, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- Not classified yetClassification not posted yetPosted 483 · 6 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic contamination controls
Procedures designed to prevent microbiological contamination of [illegible] are not established, written and followed. Specifically, A. Your firm's compounding technician was observed removing the bottle of sterile [illegible] from inside of the ISO 5 LAFH to the outside within the ISO 7 Cleanroom to disinfect their sterile gloves and failing to re-disinfect the bottle of sterile [illegible] prior to returning it to the ISO 5 LAFH. Your firm's procedure Aseptic Material Transfer from CHC Areas, HOU-OPS-017, Revision 5 fails to adequately define a method for the transfer of sterile [illegible] into and out of the ISO 5 LAFH. B. Your firm's compounding technicians were observed in the ISO 7 Cleanroom to write within each production batch record that has the potential of being a source of microorganism contamination to the ISO 5 LAFH. C. Your firm's dynamic ISO 5 LAFH smoke studies were found to be inadequate. Your technician controlling the smoke wand failed to position the wand such that the smoke pattern provided adequate coverage to assess simulated aseptic production manipulations and interventions being performed by the aseptic processing technician impacting unidirectional laminar airflow within the ISO 5 LAFH. D. During review of your firm's ISO 5 LAFH dynamic smoke studies and recording the studies within your ISO 7 Cleanroom, the studies were not performed or recorded as required by the firm's written procedure. Recording technicians' facial hair and skin were exposed within proximity of the ISO 5 LAFH resulting in a potential microbiological contamination into the ISO 7 Cleanroom and ISO 5 LAFH.
- Observation 2
Inadequate pH specification rationale
Laboratory controls do not include the established specifications and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, your firm's quality unit failed to provide an adequate scientific rationale for changing your contract testing laboratory pH test method specification from [illegible] a specification of [illegible] with BUDs of 60 or 75 days. There have been approximately [illegible] batches of Cefazolin lots compounded between September 2025 to April 2, 2026 that have been distributed. For example, your firm-initiated deviation, DEV-HOU-2025-068 dated 15-Sep-25 documented an Out-of-Specification (OOS) investigation EMPM-HOU-2025-062 to assess the pH levels of Cefazolin 1 g reconstituted in 10 mL SWFI using a 10 mL syringe and Cefazolin 1 g reconstituted in 20 mL SWFI using a 30 mL syringe. These three (3) batches included Lot #091125131102075 (BUD 11/14/2025), Lot #091125131102076 (BUD 11/14/2025) and Lot #[illegible] (BUD 11/29/2025). Your firm's documented pH specification was [illegible]. All three different lots' pH results were reported as 6.1. Your firm's 2021 and 2024 stability reports documented pH results of 6.1 after 30 days. Partly your firm's documented investigation and corrective actions performed resulting in a change in documented pH specification to [illegible]. The scientific rationale was found inadequate.
Show observations 3 to 6
- Observation 3
Stability program and data inadequate
The written stability testing program is not followed. Specifically, your firm's quality unit approved stability program is inadequate. For example, A. Your firm's 4/12/2021 stability report for three different lots documented a pH specification of [illegible] and Cefazolin assay specification of [illegible] for 10 mL syringe, NDC 73702-131-10. 1. Your records reported pH results that exceed the documented specification (pH 6.3/6.2/6.2), and Cefazolin assay documented results as low as 89 [illegible]. Your firm's contract testing laboratory has demonstrated that Cefazolin in the present formula and packaging did not meet client specification through [illegible]. The quality unit failed to provide a document containing written corrective actions; deficiencies reported by your contract laboratory were not addressed. The quality unit provided no additional stability reports supporting the finished drug products meeting the written product specification. 2. Your firm's 4/21/2021 Stability Report for Cefazolin 2 g in SWFI 10 mL, 10 mL syringe, NDC 73702-131-10; Cefazolin 2 g in SWFI 20 mL, 30 mL syringe, NDC 73702-132-10; and Cefazolin 3 g in SWFI [illegible] fail to support assigned 60- and 75-day BUDs. The stability report reported pH results that exceeded the documented specification at 30 days (pH 6.3/6.2/6.2) and Cefazolin assay documented results as low as 89 [illegible]. B. In 2024, your firm performed a stability study for three different lots of Cefazolin 1 g added to 0.9% Sodium Chloride 100 mL (1000 mg/bag) bags. 1. Your firm's quality unit failed to provide a documented specification for pH of [illegible]. The firm's quality unit approved stability reports for syringes documented a pH of [illegible] yet the finished products exceed this specification within 30 days (pH results reported of 6.1). No other stability reports for Cefazolin 1 g added to 0.9% Sodium Chloride 100 mL were provided. 2. Your firm's quality unit approved stability reports for Cefazolin 1 g added to 0.9% Sodium Chloride 100 mL Bag assigned 60- and 75-day BUDs. Reported pH and assay results exceeded the syringe filled written specifications.
- Observation 4
Released product despite failed testing
Drug products failing to meet established specifications and quality control criteria are not rejected. Specifically, during a review of your firm's compounding records and finished drug product testing, your firm's quality unit released and distributed Dextrose 50% (500 MG/ML) Repackaged [illegible] that had failed contract laboratory testing. The contract laboratory testing, using an incorrect test method, was found to be within specification using the incorrect method. An investigation by your firm's quality unit into the pH failure of Lot #091625104652129 was not adequate. Lot #091625104652129 was released and distributed. The quality unit's investigation did not include a review of other finished filling products to assess the potential that the contract laboratory method was not being accurate until this inspection's discussions with management.
- Observation 5
Unsecured printed production labels
Strict control is not exercised over labeling issued for use. Specifically, during a walk-through of your firm's Labeling Production Area, I found an unsecured unlocked storage filing cabinet containing issued printed Cefazolin labels for production use. Your firm's pharmacist and quality unit reported the key location for the unsecured unlocked cabinet was unknown at the time of the site walk-through. The area supervisor reported that the labels were removed from the cabinet at the end of the shift and returned to the label printing cage. Your firm's procedures, Labeling Procedure, HOU-OPS-019, Revision 1; and Label Control, HOU-OPS-020, Revision 1, found the discussed process for label removal at shift end was not written within your firm's procedures. The firm's quality unit was unable to provide documentation of printed labels being removed from the unsecured black cabinet and being returned to the label printing cage.
- Observation 6
Quality unit responsibilities/procedures inadequate
The responsibilities and procedures applicable to the quality control unit are not adequate. Specifically, A. Your firm's quality unit initiated CAPA HOU-2025-012 failed to define corrections to secure and control finished product labeling within your firm's product labeling production area. For example, an unsecured cabinet containing Cefazolin labels was found in the labeling production area. The firm initiated CAPA-HOU-2026-008 after being made aware on March 17, 2026 during the labeling productions area walk-through. B. Your firm's quality unit lacks the responsibility to exercise control over documents, either pending changes or in-process, obsolete procedures, or other quality records, in a manner that would ensure that they stay in a state of control. On 3/17/2026, during a walk-through of your firm's in-process and finished drug refrigeration area, I found your firm's quality unit failed to collect, review, and approve Temperature and Relative Humidity logs on in-process refrigerator, Location EQ-HOU-CSC-[illegible]-180. The records documented unit storage data ranging from 11/2025 to 02/2026. The data was recorded on obsolete forms, Cleaning, Disinfection, and Operations of Refrigerators, Freezers, and Incubators, FRM-HOU-QA-046-02, Revision 3. Your firm's quality unit currently approved form is Cleaning, Disinfection, and Operations of Refrigerators, Freezers, and Incubators, FRM-HOU-QA-046-02, Revision 5. C. Your firm's quality unit failed to ensure that Labeling Procedure, HOU-OPS-019, Revision 1; and Label Control, HOU-OPS-020, Revision 1 adequately define your firm's label control and storage within the Labeling Production Area prior to approval and release.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 9 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- FDCA 503B(a)(10)(A)
Drug product labels, fails to include
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Show 4 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- FDCA 503B(b)(2)(A)
All inclusive product report, not submitted
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 citation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jul 13, 2026. It asked for a Form 483.
Inspection ending Apr 13, 2026Not classified yet
1 request. In the inspection history above. FDA has posted its Form 483.
- Jul 13, 2026FDA-FOIA-2026-6645Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 3
- 21 CFR 211.42Design and construction features2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.125Labeling issuance1 of 3
- 21 CFR 211.192Production record review1 of 3
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- Wells Pharma of Houston, LLCD-U-N-S 055774114
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3016710931 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3016710931. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.