Cronus Pharma Specialities India Pvt Ltd
Sy. No: 99/1 Plot No. 9 (B) Gmr Hyderabad Aviation Sez, Mamidipalli Village, Shamshabad, Hyderabad, India
FEI 3015283219DUNS 876818318
FDA has 4 inspections on file for Cronus Pharma Specialities India Pvt Ltd in Hyderabad, India (FEI 3015283219), from 2022 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Three of the five FOIA requests for this site have asked FDA for this inspection's 483.
The most recent OAI inspection ended on Jan 18, 2023. No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.113(b).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2027. Its registrant is CRONUS PHARMA SPECIALITIES INDIA PRIVATE LIMITED (D-U-N-S 876818318).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2022–2025
- 2 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 5 requests, latest Nov 20, 2025
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Equipment for Environmental Control
Equipment for adequate control over micro-organisms is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
- OAISignificant objectionable conditions; FDA recommended regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Buildings of Suitable Size, Construction, Location
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.
Show 1 more citation
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the process.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Five requests to FDA under the Freedom of Information Act named this site, most recently on Nov 20, 2025. Each one asked for a Form 483.
Inspection ending Aug 20, 2025VAI
3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 15, 2026. FDAgent holds no copy that FDA posted.
- Nov 20, 2025FDA-FOIA-2025-13157Form 483· 1 of 4 sitesRecords released
- Nov 14, 2025FDA-FOIA-2025-12941Form 483· 1 of 2 sitesRecords released
- Sep 15, 2025FDA-FOIA-2025-10906Form 483Records released
Inspection ending Aug 29, 2023VAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 6, 2023FDA-FOIA-2023-8811Form 483Closed
Inspection ending Jan 18, 2023OAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- May 16, 2024FDA-FOIA-2024-4427Form 483Merged with another request
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 3
- 21 CFR 211.113Control of microbiological contamination2 of 3
- 21 CFR 211.42Design and construction features1 of 3
- 21 CFR 211.46Ventilation, air filtration, air heating and cooling1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.192Production record review1 of 3
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, relabeling, repacking
- Registration runs through
- Dec 31, 2027
- Registrant
- CRONUS PHARMA SPECIALITIES INDIA PRIVATE LIMITEDD-U-N-S 876818318
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3015283219 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3015283219. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.