Evi International Group, LLC
9110 Nw 106th St, Medley, Florida, United States
FEI 3014581785DUNS 123617598
FDA has one inspection on file for Evi International Group, LLC in Medley, Florida (FEI 3014581785). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 10 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Nine FOIA requests have asked FDA for this inspection's 483.
No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is Luis Echeverria (D-U-N-S 123617598).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2025
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 9 requests, latest May 18, 2026
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and standards designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Dates not included for each significant step
Batch production and control records do not include dates of each significant step in the manufacture and processing of the batch for each batch of drug product produced.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Show 5 more citations
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Calibration/Inspection/Checking not done
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Nine requests to FDA under the Freedom of Information Act named this site, most recently on May 18, 2026. Each one asked for a Form 483.
Inspection ending Jan 15, 2025OAI
9 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Aug 8, 2025. FDAgent holds no copy that FDA posted.
- May 18, 2026FDA-FOIA-2026-5054Form 483· 1 of 5 sitesWithdrawn
- May 18, 2026FDA-FOIA-2026-5052Form 483· 1 of 5 sitesWithdrawn
- Oct 15, 2025FDA-FOIA-2025-12014Form 483· 1 of 2 sitesRecords released
- Sep 29, 2025FDA-FOIA-2025-11395Form 483· 1 of 4 sitesRecords released
- Aug 28, 2025FDA-FOIA-2025-10330Form 483Records released
- Aug 13, 2025FDA-FOIA-2025-9661Form 483Records released
- Jul 11, 2025FDA-FOIA-2025-8580Form 483· 1 of 2 sitesClosed
- Jun 11, 2025FDA-FOIA-2025-7402Form 483· 1 of 8 sitesWithdrawn
- Apr 16, 2025FDA-FOIA-2025-3464Form 483· 1 of 5 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 9 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.166Stability testing1 of 1
Show all 9
- 21 CFR 211.188Batch production and control records1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Luis EcheverriaD-U-N-S 123617598
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3014581785 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3014581785. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.