Skip to content

Stemell Inc

27122b Paseo Espada Ste 1004, San Juan Capistrano, California, United States

FEI 3013956190

FDA has one inspection on file for Stemell Inc in San Juan Capistrano, California (FEI 3013956190). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 18 citations from this inspection: 17 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 1 under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2019
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies18 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Drug product sample

      Drug product samples are not representative of the entire batch.

    2. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt of components.

    3. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    4. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing each significant step in the operation, for each batch of drug product produced.

    5. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in processing.

    Show 13 more citations
    1. Lack of quality control unit

      There is no quality control unit.

    2. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not established and written.

    3. Aseptic Processing Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    5. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    6. Responsible person to determine, document

      The eligibility of an HCT/P donor was not by a responsible person, based on results of donor screening and donor testing.

    7. Calibration/Inspection/Checking not done

      Routine checking of electronic equipment is not performed according to a written program designed to assure proper performance.

    8. Handling and Storage to Prevent Contamination

      There was a failure to handle and store drug product containers at all times in a manner to prevent contamination.

    9. Acceptance of drug products

      Determinations of conformance to appropriate written specifications for acceptance are not made for drug products.

    10. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the to produce aseptic conditions.

    11. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the aseptic process.

    12. Quality control unit review of records

      Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    13. Drug product reserve containers

      Drug product reserve samples are not stored in the same immediate container-closure system as the marketed product.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 13

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCBER · BiologicsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3013956190 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3013956190. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.