Stemell Inc
27122b Paseo Espada Ste 1004, San Juan Capistrano, California, United States
FEI 3013956190
FDA has one inspection on file for Stemell Inc in San Juan Capistrano, California (FEI 3013956190). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 18 citations from this inspection: 17 under 21 CFR Part 211, the manufacturing rules for finished drugs, and 1 under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2019
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CBER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies18 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Drug product sample
Drug product samples are not representative of the entire batch.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt of components.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Identification of persons involved, each significant step
Batch production and control records do not include the identification of the persons performing each significant step in the operation, for each batch of drug product produced.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in processing.
Show 13 more citations
Lack of quality control unit
There is no quality control unit.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established and written.
Aseptic Processing Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Responsible person to determine, document
The eligibility of an HCT/P donor was not by a responsible person, based on results of donor screening and donor testing.
Calibration/Inspection/Checking not done
Routine checking of electronic equipment is not performed according to a written program designed to assure proper performance.
Handling and Storage to Prevent Contamination
There was a failure to handle and store drug product containers at all times in a manner to prevent contamination.
Acceptance of drug products
Determinations of conformance to appropriate written specifications for acceptance are not made for drug products.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the to produce aseptic conditions.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include validation of the aseptic process.
Quality control unit review of records
Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Drug product reserve containers
Drug product reserve samples are not stored in the same immediate container-closure system as the marketed product.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.166Stability testing1 of 1
Show all 13
- 21 CFR 211.170Reserve samples1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.198Complaint files1 of 1
- 21 CFR 1271.50How do I determine whether a donor is eligible?1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · BiologicsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3013956190 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3013956190. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.