Elroselabs Inc.
3875 Saint Johns Pkwy, Sanford, Florida, United States
FEI 3012486311
FDA has one inspection on file for Elroselabs Inc. in Sanford, Florida (FEI 3012486311). It ended on and was classified OAI, official action indicated.
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 15 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2017
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine calibration, inspection and checking of mechanical equipment is not performed according to a written program designed to assure proper performance.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Buildings not maintained in good state of repair
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Show 10 more citations
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Labeling: documentation of exam and review
There is no documentation of the examination and review of labels and labeling for conformity with established specifications and the assigning of a lot or control number.
Lack of quality control unit
There is no quality control unit.
Review of representative number of batches
Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established and written.
Cleaning/maintenance records not kept
Records are not kept for the maintenance, cleaning, sanitizing and inspection of equipment.
In-process materials characteristics testing
In-process materials are not tested for identity, strength, quality and purity and approved or rejected by the quality control unit during the production process.
Written sanitation procedures lacking
There is a lack of written procedures assigning responsibility, providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Written distribution procedure
Written distribution procedures are not established.
Regulations FDA cited here
The 14 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.56Sanitation1 of 1
- 21 CFR 211.58Maintenance1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
Show all 14
- 21 CFR 211.150Distribution procedures1 of 1
- 21 CFR 211.165Testing and release for distribution1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 1
- 21 CFR 211.186Master production and control records1 of 1
- 21 CFR 211.198Complaint files1 of 1
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3012486311 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3012486311. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.