Skip to content

fmg Co., Ltd.

72 Toegyegongdan-Gil, Chuncheon, Korea (the Republic of)

FEI 3012217889DUNS 690188305

FDA has 2 inspections on file for fmg Co., Ltd. in Chuncheon, Korea (the Republic of) (FEI 3012217889), from 2019 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.165(b), 21 CFR 211.22(d) and 21 CFR 211.25(a).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is fmg Co.Ltd (D-U-N-S 690188305).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2019–2025
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
2 requests, latest Mar 31, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Top/Middle/Bottom container sampling

      Sampling procedures are deficient regarding sampling components from the top, middle, and bottom of container.

    2. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    3. Authority lacking to review records, investigate errors

      The quality control unit lacks authority to fully investigate errors that have occurred.

    4. Written procedures fail to include

      Written procedures for cleaning and maintenance fail to include instructions for removal or obliteration of previous batch identification.

    5. Training , Education , Experience overall

      Employees engaged in the manufacture of a drug product lack the training and experience required to perform their assigned functions.

    Show 1 more citation
    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    3. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    4. Labeling Control Records and Label Copies

      The batch production and control records are deficient in that they do not include complete labeling control records, specimen and copy of labeling.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 4 more citations
    1. Labels and labeling stored separately

      Labels and other labeling materials are not stored separately with suitable identification for each different drug product, strength, dosage form or quantity of contents.

    2. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    3. Specific information required in individual logs

      Individual equipment logs do not show time, date, product and lot number of each batch processed.

    4. Representative samples after completion

      Samples of representative units were not visually examined for correct labeling at the completion of finishing operations.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Mar 31, 2026. Each one asked for a Form 483.

  • Inspection ending Jul 25, 2025VAI

    1 request. In the inspection history above. FDA released records in answer to a request for its Form 483 + EIR on Mar 18, 2026. FDAgent holds no copy that FDA posted.

    1. Mar 12, 2026FDA-FOIA-2026-2406Form 483 + EIR· 1 of 9 sitesRecords released
  • Inspection date not given

    1 request. FDA released records in answer to a request for its Form 483 + EIR on Apr 6, 2026. FDAgent holds no copy that FDA posted.

    1. Mar 31, 2026FDA-FOIA-2026-3116Form 483 + EIR· 1 of 3 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 11 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Show all 11

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing
Registration runs through
Dec 31, 2026
Registrant
fmg Co.LtdD-U-N-S 690188305

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3012217889 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3012217889. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.