Skip to content

Wells Pharmacy Inc

Dyersburg, Tennessee, United States

FEI 3011761321DUNS 057193721

FDA has 5 inspections on file for Wells Pharmacy Inc in Dyersburg, Tennessee (FEI 3011761321), from 2016 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 2 observations from the PDF; they are listed below.

The most recent OAI inspection ended on Oct 20, 2016. No warning letter, court action or import refusal is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.192, 21 CFR 211.22(c) and 21 CFR 211.42(a).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for repacking, through Dec 31, 2027. Its registrant is Wells Pharmacy, Inc (D-U-N-S 057193721).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
5, 2016–2026
1 OAI · 3 VAI · 0 NAI
Inspections with 483 observations shown
5 of 5
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
5 posted
Requested under FOIA
4 requests, latest May 18, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetClassification not posted yetOutsourcing FacilityPosted 483 · 2 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate cleaning and process validation

      Production System OBSERVATION 1 Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. Specifically, A) Inadequate Cleaning Validation Your cleaning validation (Disinfectant Efficacy Study) does not evaluate whether your current cleaning agents and procedures effectively remove hazardous drug products to prevent cross-contamination or product carryover. The cleaning agent manufacturer study provided as evidence for hazardous drug removal is inadequate for the following reasons: It only evaluated Estradiol and Progesterone not all hazardous drug products manufactured at your facility. It only tested (b) (4) surfaces, not other product contact materials such as the plastic components of your firm's metal detector. It is not representative of your current procedure. The study used brief passes with the cleaning agent, but your cleaning procedure does not require a (b) (4) pass. Your firm's pellet press and metal detector are used during the manufacturing process of all hazardous drug products such as Testosterone, Estradiol, and Progesterone. For example, your firm used the (b) (4) Tablet Press and (b) (4) Metal Detector during the production of Testosterone 50mg Cholesterol, Lot 02242026TN2, expiration date 02/11/2027 and Estradiol 6mg, Lot 11202025TN2 expiration date 11/20/2026. Both sterile finished drug products were approved and released for distribution. B) Inadequate Process Validation Your firm's process validation failed to establish scientifically justified batch pellet yield sizes for compounded products. For example, your firm has established the following pellet yield sizes without justification or rationale: Drug Product Pellet Yield Size Estradiol 6mg Estradiol 10mg (b) (4) Testosterone 50mg Cholesterol Progesterone 50mg Reviewed production batch records demonstrate significant variability in pellet weights. For example, Estradiol 10mg, lot 10212025TN3, expiration date 10/21/2026, had a total of 203 out-of-specification (OOS) pellets for weight out of [illegible] pellets inspected. This lot was approved and released for distribution. Estradiol 6mg, lot 11202025TN2, expiration date 11/20/2026, had a total of 58 OOS pellets for weight out of [illegible] pellets inspected. This lot was also approved and released for distribution. Despite these high rates of OOS pellets (43% and 28%, respectively), no investigation was performed to determine the root cause. Both lots were approved and released for distribution.

    2. Observation 2

      Inadequate laboratory specifications; hardness variability

      Laboratory Control System OBSERVATION 2 Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. Specifically, Your firm has failed to establish hardness specifications to demonstrate that these drug products conform to appropriate quality standards. Your hardness analyses demonstrate wide ranges of intra-batch results. For example, such variability was observed in the following lots: Drug Product Lot Hardness Test Results Low (kgF) Hardness Test Results High (kgF) Qty Made Qty Distributed Testosterone 50mg Cholesterol 02242026TN2 4.4 20.9 (b) (4) Testosterone/Anastrozole 08262025TN2 5.4 13.6 (b) (4) Estradiol 10mg 10212025TN3 8.3 12.7 (b) (4) Testosterone 100mg SA 01232026TN4 4.7 15.0 (b) (4) Testosterone 200mg SA 01222026TN3 13.1 20.7 (b) (4) Progesterone 100mg 04262024TN2 1.02 2.63 (b) (4) Testosterone 200mg SA 03272024TN3 4.76 11.86 (b) (4) Progesterone 100mg, Lot 04262024TN2, expiration date, received a complaint of 7 broken pellets in one order. Testosterone 200mg SA, lot 03272024TN3, expiration date, received a complaint of 3 pellets crumbling to dust when handling. Since January 2025, your firm has received 8 complaints about broken pellets out of 20 total consumer complaints. Each lot was approved and released for distribution.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and standards designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

    2. Protection from external factors

      Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.

    3. FDCA 503B(a)(10)(A)

      Drug product labels, fails to include

      The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).

    4. Controlled release dosage form testing

      Each batch of controlled-release dosage form drug product is not laboratory tested to determine conformance to the specifications for the rate of release for each active ingredient.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

    2. Complaint Investigation/Follow-Up Findings

      Complaint records are deficient in that they do not include the findings of the investigation and follow-up.

    3. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    4. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 1 more citation
    1. Supervisor Training/Education/Experience

      Individuals responsible for supervising the manufacture, processing, packing and holding of a drug product lack the training to perform their assigned functions in such a manner as to assure the drug product has the safety, identity, strength, quality and purity that it purports or is represented to possess.

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Product flow through building is inadequate

      The flow of components, drug product containers, closures and drug products though the building is not designed to prevent contamination.

    2. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    3. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.

    4. Approve or reject procedures or specs

      The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.

    5. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.

    Show 8 more citations
    1. Establishment of calibration procedures

      Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.

    2. Buildings of Suitable Size, Construction, Location

      Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

    3. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process.

    4. Quality control unit review of records

      Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    5. Mixing adequacy

      The in process control procedures were deficient in that they did not include an examination of the adequacy of mixing to assure uniformity and homogeneity.

    6. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    7. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    8. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

  6. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  7. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance6 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Facility not maintained; gaps/water damage

      Buildings used in the processing of a drug products are not maintained in a good state of repair. Specifically, 1. Multiple gaps were observed around the light fixture in the ISO 5 room. 2. Water damage was observed in the ceiling of the unclassified area adjacent to the clean room area. In addition, the unclassified area shares a wall with the clean room and multiple gaps were observed in the ceiling tiles directly above this shared wall.

    2. Observation 2

      Non-depyrogenated containers used

      Non-depyrogenated containers were used in drug production. Your drug product containers were not processed to remove pyrogenic properties to assure that they are suitable for their intended use. Specifically, the blister packaging used by the firm is not purchased as pyrogen-free and your firm does not depyrogenate this container closure prior to use.

    Show observations 3 to 6
    1. Observation 3

      Risk of cross-contamination from equipment

      The flow of drug products through the building is not designed to prevent contamination. Specifically, there is a potential risk for contamination during the compounding of bulk powdered drugs. 1. Non-dedicated equipment such as the [illegible], tablet press, and [illegible] used in the production of your firm's implantable hormonal pellets is not adequately cleaned between each batch to prevent cross-contamination.

    2. Observation 4

      Inadequate use of sporicidal agent

      The use of the sporicidal agent in the cleanrooms is inadequate. Specifically, Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Your firm fails to use a sporicidal agent in the ISO 5 area on a frequent basis. [illegible] is not an effective sporicidal agent when a [illegible] is used.

    3. Observation 5

      Inadequate environmental monitoring procedures

      Procedures designed to prevent microbiological contamination of drug products are not established, written, and followed. Specifically, your firm's written procedures, SOP 3.110-Environmental Monitoring Dyersburg, TN, states in section 8.5, [illegible]. The media fills associated with [illegible] qualification for sterile product compounding personnel are inadequate. Some deficiencies include but are not limited to: 1. The firm failed to conduct appropriate follow-up investigations and provide documentation identifying the organisms or species for each colony growth for the following [illegible] plate (Action limit [illegible] CFU): [illegible]. Plate D taken on the [illegible], was documented to have a CFU of TNTC (too numerous to count). Your firm's management stated no investigation or trending was conducted. 2. On 09/16/2016, your pharmacist failed to accurately read and/or document the environmental monitoring results for samples taken on the following dates and areas: 09/09/2016: [illegible] 09/07/2016: [illegible]

    4. Observation 6

      Smoke studies not conducted under dynamic conditions

      Your firm failed to conduct smoke studies under dynamic conditions. Specifically, the most recent qualification of the [illegible] areas completed on [illegible] by an outside contractor is not accurate in that it states it was performed under dynamic conditions. Your firm stated drug processing was not being conducted during the time of the qualification performance. In addition, the smoke study provided by your firm was not conducted under dynamic conditions.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Four requests to FDA under the Freedom of Information Act named this site, most recently on May 18, 2026.

  • Inspection ending Apr 25, 2025VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 18, 2026FDA-FOIA-2026-5052Form 483· 1 of 5 sitesWithdrawn
    2. Jul 1, 2025FDA-FOIA-2025-8119Form 483· 1 of 5 sitesRecords released
  • Inspection ending Jan 28, 2021VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Mar 13, 2026FDA-FOIA-2026-2515Form 483No records found
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Oct 24, 2024FDA-FOIA-2024-9483Inspection records· 1 of 7 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.

Show all 13

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

FDA drug establishment registration

FDA registration search
Registered operations
Repacking
Registration runs through
Dec 31, 2027
Registrant
Wells Pharmacy, IncD-U-N-S 057193721

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3011761321 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3011761321. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.