Skip to content

South Texas Botanicals

4156 Gaitan Rd, Beeville, Texas, United States

FEI 3010656208

FDA has one inspection on file for South Texas Botanicals in Beeville, Texas (FEI 3010656208). It ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 13 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2017
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance13 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures lacking for use of pesticides etc.

      Written procedures are lacking for the use of rodenticides, insecticides, fungicides and fumigating agents designed to prevent the contamination of equipment, components, drug product containers, closures, packaging, labeling materials and drug products.

    2. Results not used for expiration dates, storage cond.

      Results of stability testing are not used in determining expiration dates.

    3. Written calibration procedures

      Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions, schedules and limits for accuracy and precision.

    4. Quarantined Drug Products Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the quarantine storage of drug products prior to release.

    5. Microbiological testing

      Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

    Show 8 more citations
    1. Accurate reproduction

      The batch production and control records are deficient in that they are not an accurate reproduction of the appropriate master production or control record and checked for accuracy, dated, and signed.

    2. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Buildings not maintained in good state of repair

      Buildings used in the manufacturing, processing and holding of a drug product are not maintained in a good state of repair.

    4. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    5. Lack of quality control unit

      There is no quality control unit.

    6. Training , Education , Experience overall

      Employees engaged in the manufacture, processing, packing and holding of a drug product lack the training required to perform their assigned functions.

    7. Determination of conformance

      Determinations of conformance to appropriate written specifications for acceptance are deficient in that they are not made for each lot within each shipment of components used in the manufacture, processing, packing or holding of drug products.

    8. Procedures Written and Followed

      Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 12

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3010656208 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3010656208. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.