TRUECARE BIOMEDIX
RS 2115 College Road, Balasinor, India
FEI 3010166683DUNS 650526341
FDA has 3 inspections on file for TRUECARE BIOMEDIX in Balasinor, India (FEI 3010166683), from 2017 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. Four FOIA requests have asked FDA for this inspection's 483.
2 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 211.188(b).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant is TRUECARE BIOMEDIX (D-U-N-S 650526341).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2017–2025
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 4 requests, latest May 1, 2026
- Warning letters
- None on file
- Import refusals
- 2 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Quality unit procedures not followed
The responsibilities and procedures applicable to the quality control unit are not fully followed. Specifically, written procedures do not include sufficient details to ensure consistent implementation and written procedures are not always followed in that: i) your procedure for good documentation practices, SOP No: QA-013-01, titled Procedure for Maintaining Good Documentation Practice, Effective January 1, 2024 states, "All documents should have the signature and date of the person who prepared the document, review of the documents and approve the document." However, during a review of your log books the following was found: a) Logbook for 2023 Stability Sample Location Chart, Register Reference No: QC-042:A11, the date and signature of the employee performing the action is not documented. b) Logbook for 2025 Entry Log Card for Sample Reconciliation, Register Reference No: QC-042, the date and signature of the employee performing the reconciliation is not documented.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established, written and followed.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of recalls.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance13 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing and packing.
SOPs not followed / documented
Written production and process control procedures are not documented at the time of performance.
Test methods
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Calibration/Inspection/Checking not done
Routine inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Show 8 more citations
Dates not included for each significant step
Batch production and control records do not include dates of each significant step in the manufacture of the batch for each batch of drug product produced.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Backup data not assured as exact and complete
Backup data is not assured as exact, complete and secure from alteration, erasure or loss through keeping hard copy or alternate systems.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Sampling/testing of in-process materials
The specifications for in-process materials are deficient in that they do not include a description of the sampling plan for in-process materials.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Labeling Control Records and Label Copies
The batch production and control records are deficient in that they do not include specimen of labeling.
Written calibration procedures
Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions and schedules.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Four requests to FDA under the Freedom of Information Act named this site, most recently on May 1, 2026. Each one asked for a Form 483.
Inspection ending Feb 21, 2025VAI
4 requests. In the inspection history above. FDA has posted its Form 483.
- May 1, 2026FDA-FOIA-2026-4315Form 483Records released
- Apr 6, 2026FDA-FOIA-2026-3355Form 483Merged with another request
- Nov 26, 2025FDA-FOIA-2025-13283Form 483Records released
- Jun 20, 2025FDA-FOIA-2025-7863Form 483· 1 of 10 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.188Batch production and control records2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
Show all 11
- 21 CFR 211.170Reserve samples1 of 2
- 21 CFR 211.180General requirements1 of 2
- 21 CFR 211.194Laboratory records1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3010166683, one row per refused product line.
2 refusals on 2019-05-21 · charged NOT LISTED on 2 · no FDA sample analysis
FDA firm profile- 2019-05-21
ASPIRIN (ANALGESIC)60LAY05
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Northern Border ImportsAEK-5796533-4/91/1
- 2019-05-21
ACETAMINOPHEN (ANALGESIC)60LAY01
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Northern Border ImportsAEK-5796533-4/41/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- TRUECARE BIOMEDIXD-U-N-S 650526341
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3010166683 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3010166683. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.