Zoetis LLC
2605 E Kilgore Rd, Kalamazoo, Michigan, United States
FEI 3010146372DUNS 079995959
Company: Zoetis Inc · Linked by exact D-U-N-S match (828851555) in FDA registration data
FDA has 6 inspections on file for Zoetis LLC in Kalamazoo, Michigan (FEI 3010146372), from 2014 to 2024. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
4 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.113(b) and 21 CFR 211.22(d).
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2026. Its registrant, Zoetis Inc (D-U-N-S 828851555), has registered 10 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 6, 2014–2024
- 0 OAI · 3 VAI · 3 NAI
- Inspections with 483 observations shown
- 3 of 6
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Complete Test Data
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Show 2 more citations
Floors, walls, ceiling surfaces
Aseptic processing areas are deficient in that walls are not smooth and/or hard surfaces that are easily cleanable.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to fully investigate errors that have occurred.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Show 2 more citations
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- NAINo objectionable conditions that need follow-upVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 211.113Control of microbiological contamination3 of 3
- 21 CFR 211.22Responsibilities of quality control unit2 of 3
- 21 CFR 211.42Design and construction features2 of 3
- 21 CFR 211.56Sanitation1 of 3
- 21 CFR 211.63Equipment design, size, and location1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
Show all 10
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.194Laboratory records1 of 3
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3010146372, one row per refused product line.
4 refusals from 2025-09-03 to 2025-10-10 · charged UNAPPROVED on 4 · no FDA sample analysis
FDA firm profile- 2025-10-10
SELAMECTIN (ANTIPARASITIC)60ZPL35
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-2608138-3/10001/2
- 2025-10-10
SELAMECTIN (ANTIPARASITIC)60ZPL35
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-2608138-3/10001/1
- 2025-10-10
SELAMECTIN (ANTIPARASITIC)60ZOK35
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-2608019-5/20001/1
- 2025-09-03
SAROLANER (ANTIPARASITIC)60ZDY34
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-3446721-2/10002/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis, relabeling, repacking
- Registration runs through
- Dec 31, 2026
- Registrant
- Zoetis IncD-U-N-S 828851555
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Zoetis Inc (D-U-N-S 828851555) as the registrant for this site and the 10 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- ZOETIS BELGIUM S.ARathdrum, Ireland · FEI 30154220062 inspections2latestJan 16, 2026VAINone on file
- Zoetis Manufacturing Italia SRLCatania, Italy · FEI 30100977133 inspections3latestApr 4, 2025VAINone on file
- Zoetis Belgium S.A.Louvain-la-Neuve, Belgium · FEI 30100878426 inspections6latestMay 21, 2024NAINone on file
- Zoetis LLCLincoln, Nebraska · FEI 19101796 inspections6latestSep 29, 2023VAINone on file
- Zoetis Manufacturing & Research Spain, S.L.La Vall De Bianya, Spain · FEI 30017485055 inspections5latestJul 28, 2023VAINone on file
- Jurox Pty. LimitedRutherford, Australia · FEI 30034837295 inspections5latestJun 28, 2022VAINone on file
- ZOETIS INC.Lees Summit, Missouri · FEI 30079190641 inspection1latestOct 14, 2021NAINone on file
- Zoetis Belgium S.a.Tullamore, Ireland · FEI 30155963011 inspection1latestSep 28, 2021NAINone on file
- ZOETISLees Summit, Missouri · FEI 19220971 inspection1latestMar 18, 2015NAINone on file
- Zoetis Services LLCLees Summit, Missouri · FEI 3030978447Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3010146372 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3010146372. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.