TCA Cellular Therapy, LLC
101 Judge Tanner Blvd Ste 502, Covington, Louisiana, United States
FEI 3008829548
FDA has one inspection on file for TCA Cellular Therapy, LLC in Covington, Louisiana (FEI 3008829548). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 37 citations from this inspection: 24 under 21 CFR Part 211, the manufacturing rules for finished drugs, 9 under 21 CFR Part 1271, the rules for human cell and tissue products, and 4 under 21 CFR Part 312, the rules for investigational new drugs. They are listed below.
No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2011
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CBER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Bioresearch Monitoring37 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Inspection of packaging and labeling area
Batch production and control records do not include results of the inspection of the packaging and labeling area before and after use for each batch of drug product produced.
Description of containers and closures
Batch production and control records do not include a description of drug product containers used for each batch of drug product produced.
Cell-associated CD
Donors of leukocyte-rich cells or tissues were not tested for cell-associated communicable diseases.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Monitoring investigations
Failure to monitor the progress of an investigation conducted under your IND.
Show 32 more citations
Specific information required in individual logs
Individual equipment logs do not show time, date, product, and lot number of each batch processed.
Procedures for all other requirements
Procedures for all steps performed in the testing, screening, and determining of donor eligibility of HCT/Ps were not established.
Commercial distribution of an investigational drug
The investigational new drug was commercially distributed.
Defined areas of adequate size for operations
The control systems necessary to prevent contamination or mix-ups are deficient.
Cytomegalovirus (CMV)
Donors of viable, leukocyte-rich cells or tissue were not tested for evidence of infection due to cytomegalovirus (CMV).
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Documentation--determination, by whom, date
Documentation of the donor-eligibility determination, the responsible person who made the donor-eligibility determination, and the date of the donor-eligibility determination was not maintained.
Identification of each component or in-process material
Batch production and control records do not include the specific identification of each batch of component and in-process material used for each batch of drug product produced.
Individual inventory record
Records fail to include an individual inventory record of each component and drug product container with sufficient information to allow determination of any associated batch or lot of drug product.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors and clinical evidence of communicable disease agents and diseases.
Responsible person to determine, document
The eligibility of an HCT/P donor was not documented by a responsible person, based on results of donor screening and donor testing.
Identity of major equipment and lines used
Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.
Lack of quality control unit
There is no quality control unit.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established.
Infection with communicable disease agents
Donors were not tested for evidence of infection with communicable disease agents.
General responsibilities of sponsors
Failure to ensure the study is conducted in accordance with the protocol and/or investigational plan.
Risk factors, leukocyte-rich cells or tissues
Donors of leukocyte-rich cells or tissues were not screened by a review of relevant medical records for risk factors and clinical evidence of cell-associated communicable disease agents and diseases.
SOP for release; reactive for CMV
A standard operating procedure for the release of HCT/Ps from donors that test reactive for cytomegalovirus (CMV) was not established.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Charging for Investigational Drugs Under IND
Charges were made for the investigational drug without the prior written approval of FDA.
Components withheld from use pending release
Each lot of components and drug product containers is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Identification of persons involved, each significant step
Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.
Examination on receipt, before acceptance
Each container or grouping of containers of components and drug product containers is not examined visually upon receipt and before acceptance for appropriate labeling as to contents, container damage, broken seals, and contamination.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Written records kept in individual logs
Written records of major equipment use are not included in individual equipment logs.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, approval, and rejection of components and drug product containers.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded and justified.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Regulations FDA cited here
The 25 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.82Receipt and storage of untested components, drug product containers, and closures1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.105Equipment identification1 of 1
Show all 25
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.137Expiration dating1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.182Equipment cleaning and use log1 of 1
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.198Complaint files1 of 1
- 21 CFR 312.50General responsibilities of sponsors1 of 1
- 21 CFR 312.56Review of ongoing investigations1 of 1
- 21 CFR 1271.47What procedures must I establish and maintain?1 of 1
- 21 CFR 1271.50How do I determine whether a donor is eligible?1 of 1
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?1 of 1
- 21 CFR 1271.75How do I screen a donor?1 of 1
- 21 CFR 1271.85What donor testing is required for different types of cells and tissues?1 of 1
- 21 CFR 312.7Promotion of investigational drugs1 of 1
- 21 CFR 312.8Charging for investigational drugs under an IND1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCBER · BiologicsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008829548 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008829548. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.