Skip to content

TCA Cellular Therapy, LLC

101 Judge Tanner Blvd Ste 502, Covington, Louisiana, United States

FEI 3008829548

FDA has one inspection on file for TCA Cellular Therapy, LLC in Covington, Louisiana (FEI 3008829548). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 37 citations from this inspection: 24 under 21 CFR Part 211, the manufacturing rules for finished drugs, 9 under 21 CFR Part 1271, the rules for human cell and tissue products, and 4 under 21 CFR Part 312, the rules for investigational new drugs. They are listed below.

No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2011
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Bioresearch Monitoring37 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Inspection of packaging and labeling area

      Batch production and control records do not include results of the inspection of the packaging and labeling area before and after use for each batch of drug product produced.

    2. Description of containers and closures

      Batch production and control records do not include a description of drug product containers used for each batch of drug product produced.

    3. Cell-associated CD

      Donors of leukocyte-rich cells or tissues were not tested for cell-associated communicable diseases.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    5. Monitoring investigations

      Failure to monitor the progress of an investigation conducted under your IND.

    Show 32 more citations
    1. Specific information required in individual logs

      Individual equipment logs do not show time, date, product, and lot number of each batch processed.

    2. Procedures for all other requirements

      Procedures for all steps performed in the testing, screening, and determining of donor eligibility of HCT/Ps were not established.

    3. Commercial distribution of an investigational drug

      The investigational new drug was commercially distributed.

    4. Defined areas of adequate size for operations

      The control systems necessary to prevent contamination or mix-ups are deficient.

    5. Cytomegalovirus (CMV)

      Donors of viable, leukocyte-rich cells or tissue were not tested for evidence of infection due to cytomegalovirus (CMV).

    6. Distinctive ID or code not recorded in batch record

      The batch records do not record the distinctive identification number and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.

    7. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    8. Documentation--determination, by whom, date

      Documentation of the donor-eligibility determination, the responsible person who made the donor-eligibility determination, and the date of the donor-eligibility determination was not maintained.

    9. Identification of each component or in-process material

      Batch production and control records do not include the specific identification of each batch of component and in-process material used for each batch of drug product produced.

    10. Individual inventory record

      Records fail to include an individual inventory record of each component and drug product container with sufficient information to allow determination of any associated batch or lot of drug product.

    11. Risk factors, clinical evidence

      Donors were not screened by a review of relevant medical records for risk factors and clinical evidence of communicable disease agents and diseases.

    12. Responsible person to determine, document

      The eligibility of an HCT/P donor was not documented by a responsible person, based on results of donor screening and donor testing.

    13. Identity of major equipment and lines used

      Batch production and control records do not include the identity of individual major equipment used for each batch of drug product produced.

    14. Lack of quality control unit

      There is no quality control unit.

    15. Expiration date lacking

      Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.

    16. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices.

    17. Procedures to be written and followed

      Procedures describing the handling of all written and oral complaints regarding a drug product are not established.

    18. Infection with communicable disease agents

      Donors were not tested for evidence of infection with communicable disease agents.

    19. General responsibilities of sponsors

      Failure to ensure the study is conducted in accordance with the protocol and/or investigational plan.

    20. Risk factors, leukocyte-rich cells or tissues

      Donors of leukocyte-rich cells or tissues were not screened by a review of relevant medical records for risk factors and clinical evidence of cell-associated communicable disease agents and diseases.

    21. SOP for release; reactive for CMV

      A standard operating procedure for the release of HCT/Ps from donors that test reactive for cytomegalovirus (CMV) was not established.

    22. Quality control unit review of records

      Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.

    23. Charging for Investigational Drugs Under IND

      Charges were made for the investigational drug without the prior written approval of FDA.

    24. Components withheld from use pending release

      Each lot of components and drug product containers is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.

    25. Identification of persons involved, each significant step

      Batch production and control records do not include the identification of the persons performing, directly supervising, and checking each significant step in the operation, for each batch of drug product produced.

    26. Examination on receipt, before acceptance

      Each container or grouping of containers of components and drug product containers is not examined visually upon receipt and before acceptance for appropriate labeling as to contents, container damage, broken seals, and contamination.

    27. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

    28. Written records kept in individual logs

      Written records of major equipment use are not included in individual equipment logs.

    29. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, approval, and rejection of components and drug product containers.

    30. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

    31. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    32. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

Regulations FDA cited here

The 25 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 25

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCBER · BiologicsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3008829548 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3008829548. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.