Skip to content

Excel Vision

Zone Industrielle, 27 Rue De La Lombardiere, Annonay, Ardeche, France

FEI 3007058211DUNS 274234566

FDA has 7 inspections on file for Excel Vision in Annonay, Ardeche (FEI 3007058211), from 2012 to 2026. The latest ended on and was classified OAI, official action indicated. FDA has issued 2 warning letters under this FEI, the latest on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 11 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Two of the 12 FOIA requests for this site have asked FDA for this inspection's 483.

FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action or import refusal is filed under this FEI.

One regulation was cited at more than one inspection: 21 CFR 211.113(b).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Excelvision (D-U-N-S 274234566).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
7, 2012–2026
2 OAI · 5 VAI · 0 NAI
Inspections with 483 observations shown
3 of 7
Form 483s posted by FDA
↗
2 posted
Requested under FOIA
12 requests, latest FY2023
Warning letters
· CDER ↗
2 on file
Import refusals
None under this FEI
Import alerts
66-40Red List
Matched on FDA’s firm name and street address
Drug establishment registration
Through

Inspection history

7 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 11 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    3. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    4. Written in-process control procedures

      Written procedures are not established that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.

    5. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    Show 6 more citations
    1. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

    2. Review of representative number of batches

      Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.

    3. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    4. Floors, walls, ceiling surfaces

      Aseptic processing areas are deficient in that floors, walls and ceilings are not smooth and/or hard surfaces that are easily cleanable.

    5. Computer control of master formula records

      Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.

    6. Cleaning/maintenance records not kept

      Records are not kept for the maintenance and inspection of equipment.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate complaint investigations

      Written records of investigations into unexpla [illegible] conclusions and follow-up. Specifically, From 01/2023 to date, about 120 complaints from the U.S. market [regarding] specks, and discoloration being observed on the [illegible] drug products manufactured in Building [illegible] (b)(4) products different batches. Your firm's complaint investigations are inadequate [illegible] patient safety. Specifically, A. We reviewed about 40 investigations, all concluded that the mold is probably due to improper use and/or storage of the product bottle by the patients. No non-conformity could be identified within Excelvision. However, you do not have documented evidence to support handling by the end-users being the root cause [illegible] were contacted or interviewed indicating improper use. B. Investigations do not always include microbiological testing [to determine] the identity of the black specks, mold, or discoloration. The following are examples: complaint samples returned to the firm. No microbiological tests (i.e., sterility test) were performed, these samples were later discarded. Complaint # / Product / Batch & Date B11131 08/06/2024 B11132 08/07/2024 B11183 09/10/2024 B11248 10/07/2024 Retention samples from the complaint batches are examined by quality assurance (QA) technicians. C. [illegible] technicians [illegible] the presence of microbial growth incl[uding mold species].

    2. Observation 2

      Inadequate smoke/Media Fill validation

      Procedures designed to prevent microbiological contamination of sterile [illegible] did not include adequate validation. Smoke Studies: A. Air flow visualization studies (smoke studies) do not provide assurance that unidirectional air flow (first air) is maintained. We reviewed smoke studies conducted on 06/2024 for the (b)(4) line (b)(4) located in Building [illegible] (b)(4) products for the U.S. market and for [illegible], including but were not limited to the following: a) Aseptic operators did not observe slow and deliberate movement while working in classified Grade A and Grade B cleanrooms. They performed aseptic activities using quick and abrupt motions that disrupted the [illegible]. b) Operator's body was observed leaning into the Grade A area while performing interventions. c) During (b)(4) interventions, smoke was observed blown horizontally toward the operator and out to the Grade B areas, leaving the Grade A critical zones without any unidirectional and downward HEPA coverage. d) Swirl and stagnate airflow was observed in the [illegible] Air Supply area. e) During (b)(4) interventions, the Grade A side [illegible] Grade B environment. However, it was not sanitized prior to intervention. f) Operators sanitized their hands but not their wrist and forearm areas with [illegible] before reaching into the Grade A fill [illegible] dry before conducting interventions. g) Operators [illegible] observed spraying [illegible] (bottles and (b)(4) or open (b)(4) plate). Media Fills (MFs): B. We watched videos of aseptic process simulation (b)(4) conducted in (b)(4) fill line on 10/ (b)(4) products for the U.S. market and for [illegible]. We noted: We watched the video footage of [illegible] the Grade B storage area to the bottle loading zone [illegible]. We observed one of the [illegible] operators transported the bags inside the Grade A [illegible] the bottles in a quick motion. Material surfaces should be adequately sanitized before moving them into the Grade A fill line area. Bottles, [illegible] and deliberate motion to avoid disrupting the laminar [illegible]. C. Interventions performed during commercial filling operations are [illegible] on intervention type, frequency, and duration. There is a lack of sterility assurance for aseptic filling performed and for sterile [illegible] products already in the market if MF [illegible] was noted: a) Interventions identified as worst case are required [to be] study. b) Commercial filling interventions [illegible] (b)(4). [Illegible] filling of [illegible] performed including but not limited to: • Intervention 1101 • Intervention 117 (overload of [illegible]) • The filling line was stopped/paused for 2 hours and 45 minutes waiting for maintenance personnel to perform machine adjustment. However, the above intervention types and durations were not simulated during [illegible] Batch dated 10/23/2024.

    Show observations 3 to 5
    1. Observation 3

      Cleaning validation and work instructions lacking

      Aseptic processing areas are deficient regarding [illegible] and equipment to produce aseptic conditions. A. [illegible] are being used to clean the [illegible] surfaces. However, you do not have a validation study against mold species. B. Work instruction (WI) [illegible] the (b)(4) filling machine surfaces. For example, the bottle bowl comes into contact with sterile bottles used to fill the sterile [illegible]. The above WI is to "Clean the inside of the bottle bowl." (b)(4) does not have adequate cleaning details to prevent microbial contamination of sterile [illegible].

    2. Observation 4

      Non-cleanable/damaged fill line surfaces

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. Specifically, Your firm's aseptic fill line does not always contain smooth and easy to clean surfaces to prevent microbial contamination. On 11/18/2024, I (AMH) conducted a walkthrough inspection of the (b)(4) fill line located in Room [illegible] of Building [illegible] (b)(4) products for the U.S. market. I observed what appeared to be deep cracks and heavy scratch marks on the outside of the Grade A fill line (bottle conveying) and Zone [illegible] (bottle conveying). As per the Contamination Strategy classified cleanroom surfaces should be smooth and easy to clean.

    3. Observation 5

      Lab records lack second-person review initials

      Laboratory records do not include the initials or signature indicating that the original records have been reviewed for accuracy, completeness, compliance with established standards. Specifically, On 11/13/2024, I (EL) reviewed the [illegible] surface monitoring records. (b)(4) up to of the total colony enumerations. The discrepancy was confirmed [illegible]. Environmental monitoring data is not subject to second-person review to make certain that all test results and associated information are appropriately reported.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  4. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    2. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

    4. Lab controls established, including changes

      The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.

  7. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

12 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Jan 22, 2026OAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Apr 30, 2026FDA-FOIA-2026-4268Form 483· 1 of 3 sitesClosed, no reply from requester
    2. Apr 22, 2026FDA-FOIA-2026-4060Form 483Records released
  • Inspection ending Nov 19, 2024OAI

    4 requests. In the inspection history above. FDA has posted its Form 483.

    1. Apr 27, 2026FDA-FOIA-2026-4158Form 483Records released
    2. Jul 24, 2025FDA-FOIA-2025-9045Inspection recordsClosed
    3. Mar 26, 2025FDA-FOIA-2025-2777Form 483Closed
    4. Mar 14, 2025FDA-FOIA-2025-2373Inspection recordsClosed
  • Inspection ending Jul 7, 2023VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Feb 7, 2024FDA-FOIA-2024-1353Form 483Closed
  • Inspection date not given

    5 requests. FDA released records in answer to a request for its Form 483 + EIR on May 6, 2026. FDAgent holds no copy that FDA posted.

    1. FY2023FDA-FOIA-2023-7362Inspection recordsClosed
    2. May 12, 2026FDA-FOIA-2026-4865Form 483Records released
    3. Apr 22, 2026FDA-FOIA-2026-4072Form 483Withdrawn
    4. Apr 14, 2026FDA-FOIA-2026-3736Form 483 + EIRRecords released
    5. May 12, 2025FDA-FOIA-2025-4311Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 9 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 7 inspections, with how many of them cited each.

Show all 9

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2026-04-27

    FDA’s entry
    Excel Vision · Zone Industrielle, 27 Rue De La Lombardiere, Annonay, Ardeche FRANCE
    FDA’s inspection record for FEI 3007058211
    Excel Vision · Zone Industrielle, 27 Rue De La Lombardiere, Annonay, France

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    15 products

    • 54 - D - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx 1 Ingr
    • 54 - E - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Human N/Rx Comb Ingr
    • 54 - F - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx 1 Ingr
    Show 12 more products
    • 54 - G - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Hum Rx Comb Ingr
    • 54 - I - --Vitamins/Minerals (Human/Animal); Proteins/Unconv Dietary Supp (Human), Investigational
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
ExcelvisionD-U-N-S 274234566

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3007058211 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3007058211. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.