Skip to content

Frontage Laboratories, Inc.

700 Pennsylvania Dr, Exton, Pennsylvania, United States

FEI 3006799640DUNS 144864716

FDA has 15 inspections on file for Frontage Laboratories, Inc. in Exton, Pennsylvania (FEI 3006799640), from 2009 to 2026. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Two of the five FOIA requests for this site have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.160(b) and 21 CFR 211.192.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling, analysis, relabeling and repacking, through Dec 31, 2026. Its registrant is Frontage Laboratories, Inc. (D-U-N-S 113634187).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
15, 2009–2026
0 OAI · 5 VAI · 10 NAI
Inspections with 483 observations shown
2 of 15
Form 483s posted by FDA
↗
Requested under FOIA
5 requests, latest Oct 15, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

15 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch MonitoringCitations not published
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 4 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.

    2. Backup file not maintained

      Failure to maintain a backup file of data entered into the computer or related system.

    3. Data secured in course of each test

      Laboratory records do not include a complete record of all data secured in the course of each test, including all charts and spectra from laboratory instrumentation, properly identified to show the.

    4. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  3. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food Additives3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.

    2. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    3. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.

  5. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
  9. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  10. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  11. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  12. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  13. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  14. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  15. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Five requests to FDA under the Freedom of Information Act named this site, most recently on Oct 15, 2026.

  • Inspection ending Jun 18, 2026VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Sep 30, 2026. FDAgent holds no copy that FDA posted.

    1. Oct 15, 2026FDA-FOIA-2026-10044Form 483· 1 of 4 sitesRecords released
    2. Sep 21, 2026FDA-FOIA-2026-9135Form 483· 1 of 5 sitesRecords released
  • Inspection ending Apr 14, 2026VAI

    2 requests. In the inspection history above. FDA has posted its Form 483.

    1. Jun 8, 2026FDA-FOIA-2026-5618Form 483Records released
    2. Jun 3, 2026FDA-FOIA-2026-5515Form 483· 1 of 5 sitesRecords released
  • Inspection date not given

    1 request. FDA released records in answer to a request for its EIR on Sep 15, 2026. FDAgent holds no copy that FDA posted.

    1. Jan 6, 2026FDA-FOIA-2026-149EIRRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 15 inspections, with how many of them cited each.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis, relabeling, repacking
Registration runs through
Dec 31, 2026
Registrant
Frontage Laboratories, Inc.D-U-N-S 113634187

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other FEIs recorded as Frontage Laboratories, Inc.

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006799640 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006799640. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.