Skip to content

Resilience US, Inc.

8814 Trade Port Dr # 8848, West Chester, Ohio, United States

FEI 3006316363DUNS 118917882

FDA has 14 inspections on file for Resilience US, Inc. in West Chester, Ohio (FEI 3006316363), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. Five of the nine FOIA requests for this site have asked FDA for this inspection's 483.

The most recent OAI inspection ended on Dec 23, 2009. No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.100(b) and 21 CFR 211.113(b).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Resilience US, LLC (D-U-N-S 117857634).

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
14, 2009–2025
1 OAI · 4 VAI · 9 NAI
Inspections with 483 observations shown
3 of 14
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Requested under FOIA
9 requests, latest Apr 9, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

14 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Complete test data included in records

      Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.

    2. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    3. Microbiological Contamination Exam

      Each lot of a drug product container and closure that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use.

    4. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    5. Identification of Person Performing Review of Lab Records

      Laboratory records are deficient in that they do not include the initials and signature of the second person reviewing the record for accuracy.

    Show 1 more citation
    1. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.

  2. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

    2. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  7. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  10. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Following/documenting laboratory controls

      Established sampling plans are not followed.

    2. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Mix-up

      An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning an incident that caused a drug product or its labeling to be applied to another article.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.

    5. SOPs not followed / documented

      Written production and process control procedures are not followed in the execution of production and process control functions.

  11. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  12. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  13. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  14. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  15. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Nine requests to FDA under the Freedom of Information Act named this site, most recently on Apr 9, 2026. Each one asked for a Form 483.

  • Inspection ending Jan 21, 2025VAI

    5 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 30, 2025. FDAgent holds no copy that FDA posted.

    1. Sep 29, 2025FDA-FOIA-2025-11393Form 483· 1 of 4 sitesRecords released
    2. Jul 18, 2025FDA-FOIA-2025-8801Form 483· 1 of 3 sitesRecords released
    3. Jun 16, 2025FDA-FOIA-2025-7676Form 483· 1 of 10 sitesWithdrawn
    4. Apr 30, 2025FDA-FOIA-2025-3902Form 483Closed
    5. Mar 25, 2025FDA-FOIA-2025-2759Form 483· 1 of 4 sitesClosed
  • Inspection ending May 25, 2022

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Nov 28, 2023FDA-FOIA-2023-10622Form 483Closed
  • Inspection date not given

    3 requests. FDA released records in answer to a request for its Form 483 + EIR on Apr 20, 2026. FDAgent holds no copy that FDA posted.

    1. Apr 9, 2026FDA-FOIA-2026-3500Form 483 + EIR· 1 of 9 sitesRecords released
    2. Mar 7, 2025FDA-FOIA-2025-2158Form 483Closed
    3. Feb 11, 2025FDA-FOIA-2025-1377Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 10 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 14 inspections, with how many of them cited each.

Show all 10

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Resilience US, LLCD-U-N-S 117857634

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other FEIs recorded as Resilience US, Inc.

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

  • Resilience US, Inc.FEI 1000305672Allston, Massachusetts, United States

    Last inspected 2019-08-21NAI

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006316363 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006316363. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.