Skip to content

AmLion Toothpaste Mfg Sdn

Lot 4, Gate A, Jalan Teknologi 3/6, Seksyn 3, Taman Sains Selangor, Petaling Jaya, Malaysia

FEI 3006057298

FDA has 3 inspections on file for AmLion Toothpaste Mfg Sdn in Petaling Jaya, Malaysia (FEI 3006057298), from 2015 to 2023. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

13 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.

Six regulations were cited at more than one inspection; they are listed below.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2015–2023
1 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
Form 483s posted by FDA
None held for this FEI
Import refusals
13 refusals
Import alerts
66-40Red List
Matched on FDA’s firm name and street address

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.

    2. Lack of quality control unit

      There is no quality control unit.

    3. Procedures for non-sterile drug products

      Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

    4. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.

    5. Component identity verification

      Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.

    Show 2 more citations
    1. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    2. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    2. Component identity verification

      Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.

    3. Valid stability test methods

      The written stability program for drug products does not include reliable, meaningful and specific test methods.

    4. Cleaning / Sanitizing / Maintenance

      Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.

    5. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.

    Show 1 more citation
    1. Weights and Measures of Components Used

      The batch production and control records are deficient in that they do not include weights and measures of components used in the process.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance16 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Actual vs. theoretical yields not determined

      Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and packaging of the drug product.

    2. Return of labeling

      Returned labeling is not maintained and stored in a manner to provide proper identification.

    3. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded.

    4. Reporting of adverse drug experience to FDA

      Written procedures describing the handling of all written and oral complaints do not include provisions for review to determine whether the complaint represents a serious and unexpected adverse drug experience which is required to be reported to the Food and Drug Administration.

    5. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    Show 11 more citations
    1. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    2. Valid stability test methods

      The written stability program for drug products does not include meaningful test methods.

    3. Identification of containers, lines, equipment

      All major equipment used during the production of a batch of drug product is not properly identified at all times to indicate contents and the phase of processing of the batch.

    4. Drug products - samples representative, identified properly

      Samples taken of drug products for determination of conformance to written specifications are not representative.

    5. Representative Samples

      Representative samples are not taken of each shipment of each lot of components for testing or examination.

    6. Sample size - test intervals

      The written stability program for drug products does not include sample size based on statistical criteria for each attribute examined to assure valid estimates of stability.

    7. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.

    8. Control procedures to monitor and validate performance

      Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    9. Written calibration / inspection records not kept

      Records of the calibration checks and inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.

    10. Written procedures not established/followed

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    11. Lack of quality control unit

      There is no quality control unit.

Regulations FDA cited here

The 16 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.

Show all 16

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Import refusals

FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3006057298, one row per refused product line.

13 refusals from 2018-08-30 to 2023-12-12 · charged DRUG GMPS on 12, DIRECTIONS on 1 · no FDA sample analysis

FDA firm profile
  • 2023-12-12

    STANNOUS FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RAY06

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Northern Border ImportsWRT-1687887-0/111/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/91/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/81/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/71/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/61/1

Show 8 more
  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/51/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/41/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/31/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/21/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/111/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/11/1

  • 2023-09-25

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04

    DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION

    Division of Southwest Imports655-2492828-4/101/1

  • 2018-08-30

    SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBL04

    DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING

    N-RX INACT 502(e)(1); 801(a)(3); Misbranding

    LACKS N/C 502(b)(2), 801(a)(3); MISBRANDING

    Division of Northern Border ImportsWRT-1546670-1/111/1

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2023-08-17

    FDA’s entry
    AmLion Toothpaste Mfg Sdn · Lot 4, Gate A, Jalan Teknologi 3/6, Seksyn 3, Taman Sains Selangor, Petaling Jaya, Selangor MALAYSIA
    FDA’s inspection record for FEI 3006057298
    AmLion Toothpaste Mfg Sdn · Lot 4, Gate A, Jalan Teknologi 3/6, Seksyn 3, Taman Sains Selangor, Petaling Jaya, Malaysia

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    11 products

    • 53 I - - 01Dentifrices (Aerosol, Liquid, Toothpastes, Toothpowders), without Fluoride (Oral Hygiene Products)
    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    Show 8 more products
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3006057298 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3006057298. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.