AmLion Toothpaste Mfg Sdn
Lot 4, Gate A, Jalan Teknologi 3/6, Seksyn 3, Taman Sains Selangor, Petaling Jaya, Malaysia
FEI 3006057298
FDA has 3 inspections on file for AmLion Toothpaste Mfg Sdn in Petaling Jaya, Malaysia (FEI 3006057298), from 2015 to 2023. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
13 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 3, 2015–2023
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- 13 refusals
- Import alerts
- 66-40Red List
- Matched on FDA’s firm name and street address
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Lack of quality control unit
There is no quality control unit.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Show 2 more citations
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Valid stability test methods
The written stability program for drug products does not include reliable, meaningful and specific test methods.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Storage under appropriate conditions
Drug products are not stored under appropriate conditions of temperature and humidity so that their identity, strength, quality, and purity are not affected.
Show 1 more citation
Weights and Measures of Components Used
The batch production and control records are deficient in that they do not include weights and measures of components used in the process.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance16 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and packaging of the drug product.
Return of labeling
Returned labeling is not maintained and stored in a manner to provide proper identification.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not recorded.
Reporting of adverse drug experience to FDA
Written procedures describing the handling of all written and oral complaints do not include provisions for review to determine whether the complaint represents a serious and unexpected adverse drug experience which is required to be reported to the Food and Drug Administration.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Show 11 more citations
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Valid stability test methods
The written stability program for drug products does not include meaningful test methods.
Identification of containers, lines, equipment
All major equipment used during the production of a batch of drug product is not properly identified at all times to indicate contents and the phase of processing of the batch.
Drug products - samples representative, identified properly
Samples taken of drug products for determination of conformance to written specifications are not representative.
Representative Samples
Representative samples are not taken of each shipment of each lot of components for testing or examination.
Sample size - test intervals
The written stability program for drug products does not include sample size based on statistical criteria for each attribute examined to assure valid estimates of stability.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Written calibration / inspection records not kept
Records of the calibration checks and inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Lack of quality control unit
There is no quality control unit.
Regulations FDA cited here
The 16 sections of 21 CFR in FDA’s published citations for this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance3 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures3 of 3
- 21 CFR 211.100Written procedures; deviations3 of 3
- 21 CFR 211.166Stability testing3 of 3
- 21 CFR 211.22Responsibilities of quality control unit2 of 3
- 21 CFR 211.142Warehousing procedures2 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.103Calculation of yield1 of 3
Show all 16
- 21 CFR 211.105Equipment identification1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.113Control of microbiological contamination1 of 3
- 21 CFR 211.125Labeling issuance1 of 3
- 21 CFR 211.160General requirements1 of 3
- 21 CFR 211.170Reserve samples1 of 3
- 21 CFR 211.188Batch production and control records1 of 3
- 21 CFR 211.198Complaint files1 of 3
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsLetter on fda.govFDA record
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3006057298, one row per refused product line.
13 refusals from 2018-08-30 to 2023-12-12 · charged DRUG GMPS on 12, DIRECTIONS on 1 · no FDA sample analysis
FDA firm profile- 2023-12-12
STANNOUS FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RAY06
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border ImportsWRT-1687887-0/111/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/91/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/81/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/71/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/61/1
Show 8 more
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/51/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/41/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/31/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/21/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/111/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/11/1
- 2023-09-25
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBG04
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Southwest Imports655-2492828-4/101/1
- 2018-08-30
SODIUM FLUORIDE (DENTAL CARIES PROPHYLACTIC)63RBL04
DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING
N-RX INACT 502(e)(1); 801(a)(3); Misbranding
LACKS N/C 502(b)(2), 801(a)(3); MISBRANDING
Division of Northern Border ImportsWRT-1546670-1/111/1
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov
Date published 2023-08-17
- FDA’s entry
- AmLion Toothpaste Mfg Sdn · Lot 4, Gate A, Jalan Teknologi 3/6, Seksyn 3, Taman Sains Selangor, Petaling Jaya, Selangor MALAYSIA
- FDA’s inspection record for FEI 3006057298
- AmLion Toothpaste Mfg Sdn · Lot 4, Gate A, Jalan Teknologi 3/6, Seksyn 3, Taman Sains Selangor, Petaling Jaya, Malaysia
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
11 products
- 53 I - - 01Dentifrices (Aerosol, Liquid, Toothpastes, Toothpowders), without Fluoride (Oral Hygiene Products)
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 56 - - - --Antibiotics (Human/Animal)
Show 8 more products
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
- 60 - - - --Human and Animal Drugs
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3006057298 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3006057298. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.