Skip to content

Samson Pharmaceuticals, Inc

5635 Smithway St, Commerce, California, United States

FEI 3005644727DUNS 088169581

FDA has 3 inspections on file for Samson Pharmaceuticals, Inc in Commerce, California (FEI 3005644727), from 2016 to 2026. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below. One of the two FOIA requests for this site has asked FDA for this inspection's 483.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Three regulations were cited at more than one inspection: 21 CFR 211.113(b), 21 CFR 211.160(a) and 21 CFR 211.160(b)(4).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2027. Its registrant is Samson Pharmaceuticals, Inc. (D-U-N-S 088169581).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2016–2026
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 3
Form 483s posted by FDA
↗
Requested under FOIA
2 requests, latest Jul 13, 2026
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Establish reliability of supplier's C of A

      Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.

    2. No written record of investigation

      Written records are not always made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.

    3. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

    4. Calibration - at intervals, written program, remedial action

      The calibration of instruments is not done at suitable intervals in accordance with an established written program.

    5. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    Show 3 more citations
    1. Lab controls established, including changes

      The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit.

    2. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance16 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    2. Aseptic Processing Area

      Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.

    3. Following/documenting laboratory controls

      Established laboratory control mechanisms are not followed and documented at the time of performance.

    4. Acceptance criteria for sampling & testing

      Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release.

    5. Storage under appropriate conditions

      Drug products are not stored under appropriate conditions of temperature, humidity and light so that their identity, strength, quality, and purity are not affected.

    Show 11 more citations
    1. Rejecting When Specifications Not Met

      Failure to reject any lot of components that did not meet the appropriate written specifications for identity, strength, quality, and purity.

    2. In-process materials characteristics testing

      In-process materials are not tested for quality and approved or rejected by the quality control unit during the production process.

    3. Establishment of calibration procedures

      Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.

    4. Control procedures to monitor and validate performance

      Control procedures are not established which of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.

    5. Floors, walls, ceiling surfaces

      Aseptic processing areas are deficient in that floors, walls and ceilings are not smooth and/or hard surfaces that are easily cleanable.

    6. Defined areas of adequate size for operations

      The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.

    7. Identity Testing of Each Component

      The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.

    8. Tentative expiration date

      Where data from accelerated studies was used to project a tentative expiration date beyond a date supported by actual shelf life studies, there were no stability studies and drug product testing at appropriate intervals conducted until the tentative expiration date was verified or the appropriate expiration date determined.

    9. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.

    10. Items to cover on annual reviews

      Written procedures are not followed for evaluations done at least annually and including provisions for a review of investigations conducted for each drug product.

    11. Test methods

      The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.

  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Two requests to FDA under the Freedom of Information Act named this site, most recently on Jul 13, 2026. Each one asked for a Form 483.

  • Inspection ending Apr 29, 2026OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Jul 13, 2026FDA-FOIA-2026-6645Form 483· 1 of 5 sitesRecords released
  • Inspection date not given

    1 request. None of FDA’s log entries for these requests say records were released.

    1. Aug 5, 2025FDA-FOIA-2025-9474Form 483 + EIRReferred to Alternative Access Process

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 12 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.

Show all 12

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling
Registration runs through
Dec 31, 2027
Registrant
Samson Pharmaceuticals, Inc.D-U-N-S 088169581

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005644727 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005644727. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.