Skip to content

Utah Cord Bank LLC

8675 S Sandy Pkwy Ste 110, Sandy, Utah, United States

FEI 3005351861

FDA has 6 inspections on file for Utah Cord Bank LLC in Sandy, Utah (FEI 3005351861), from 2009 to 2023. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

FDA published one citation from this inspection, under 21 CFR Part 1271, the rules for human cell and tissue products. It is listed below.

FDA has issued 2 warning letters under this FEI, the latest on (CBER · Office of Biological Products Operations - Division 2). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
6, 2009–2023
0 OAI · 0 VAI · 6 NAI
Inspections with 483 observations shown
2 of 6
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood Products1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Contamination, mix ups, improper release

      Storage areas and stock rooms were not controlled to prevent mix-ups, contamination and cross contamination of HCT/Ps, supplies and reagents and to prevent HCT/Ps from improperly being made available for distribution.

  2. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic Products19 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Prepared for each batch, include complete information

      Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.

    2. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.

    3. Computer software verification

      The performance of computer software has not been verified.

    4. Infection with communicable disease agents

      Donors were not tested for evidence of infection with relevant communicable disease agents.

    5. Process validation procedures

      Procedures to validate and approve processes that cannot be fully verified by inspection and tests were not established.

    Show 14 more citations
    1. Risk factors, clinical evidence

      Donors were not screened by a review of relevant medical records for risk factors and clinical evidence of communicable disease agents and diseases.

    2. Written procedures not established/followed

      Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Management system, other records

      Records pertinent to the manufacture of HCT/Ps were not maintained and organized under the records management system.

    4. Determination based on screening and testing

      HCT/P donors were not determined to be eligible based on the results of donor screening and testing.

    5. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    6. Lot or control number assigned

      The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.

    7. Procedures to meet core CTGP

      Procedures appropriate to meet core CGTP requirements for all steps that you perform in the manufacture of HCT/Ps were not established, maintained and defined.

    8. Validation lacking for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.

    9. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    10. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval and rejection of components, drug product containers and closures.

    11. Investigations of discrepancies, failures

      There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    12. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    13. Lack of written stability program

      There is no written testing program designed to assess the stability characteristics of drug products.

    14. Scientifically sound laboratory controls

      Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components, drug product containers and closures conform to appropriate standards of identity, strength, quality and purity.

  3. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  4. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  5. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  6. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone

Regulations FDA cited here

The 20 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 6 inspections, with how many of them cited each.

Show all 20

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3005351861 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3005351861. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.