Mariposa Labs, LLC
270 E 50th St, Boise, Idaho, United States
FEI 3004003370
FDA has 2 inspections on file for Mariposa Labs, LLC in Boise, Idaho (FEI 3004003370), from 2013 to 2018. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 14 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 2, 2013–2018
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance14 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance.
Testing in same container - closure system
The written stability program does not assure testing of the drug product in the same container-closure system as that in which the drug product is marketed.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Show 9 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations.
Establish reliability of supplier's C of A
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Written record of investigation incomplete
Written records of investigations into the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Procedures for non-sterile drug products
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed.
Following/documenting laboratory controls
Established specifications are not followed.
Written complaint record must include
Written complaint records do not include, where known, the name and strength of the drug product, lot number and name of complainant.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Show 3 more citations
Cleaning SOPs/instructions
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Theoretical yield statement including percentages
Master production and control records lack a statement of theoretical yield including the maximum and minimum percentages of theoretical yield beyond which investigation is required.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Regulations FDA cited here
The 13 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.192Production record review2 of 2
- 21 CFR 211.198Complaint files2 of 2
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
- 21 CFR 211.113Control of microbiological contamination1 of 2
Show all 13
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.186Master production and control records1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004003370 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004003370. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.