The Micro Connection Enterprises, Inc. DBA Personal Care Performance Group
13290 Daum Dr, City Of Industry, California, United States
FEI 3003964498
FDA has 8 inspections on file for The Micro Connection Enterprises, Inc. DBA Personal Care Performance Group in City Of Industry, California (FEI 3003964498), from 2008 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
No warning letter, court action or import refusal is filed under this FEI.
Five regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2008–2022
- 0 OAI · 7 VAI · 1 NAI
- Inspections with 483 observations shown
- 4 of 8
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written program not followed
The written stability testing program is not followed.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
- 21 CFR 11
Electronic records
Electronic records are used, but they do not meet retention, system access limitation and audit trail requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Review of representative number of batches
Written procedures are not established and followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Manufacturing Instructions and Specifications
The master production and control records are deficient in that they do not include complete manufacturing, control, instructions, procedures, special notations and precautions.
Accelerated stability studies
Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Show 1 more citation
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing and packaging of the drug product.
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Written program not followed
The written stability testing program is not followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals with provisions for remedial action in the event accuracy and/or precision limits are not met.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
In-process samples representative, identified properly
Samples taken of in-process materials for determination of conformance to specifications are not representative.
Sample size - test intervals
The written stability program for drug products does not include sample size and test intervals based on statistical criteria for each attribute examined to assure valid estimates of stability.
Show 7 more citations
Signature and checking of records -- 2 persons
The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Actual yield, % of theoretical yield
The batch production and control records do not include a statement of the actual yield at appropriate stages of processing for each batch of drug product produced.
Components withheld from use pending release
Each lot of components is not withheld from use until the lot has been sampled, tested, examined, and released by the quality control unit.
Identification of persons involved, each significant step
Batch production and control records do not include the identification of the persons performing and directly supervising each significant step in the operation, for each batch of drug product produced.
Lab controls established, including changes
The establishment of test procedures including any changes thereto, are not reviewed and approved by the quality control unit.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.166Stability testing4 of 4
- 21 CFR 211.160General requirements3 of 4
- 21 CFR 211.22Responsibilities of quality control unit2 of 4
- 21 CFR 211.100Written procedures; deviations2 of 4
- 21 CFR 211.180General requirements2 of 4
- 21 CFR 211.186Master production and control records2 of 4
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 4
- 21 CFR 211.103Calculation of yield1 of 4
Show all 11
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 4
- 21 CFR 211.188Batch production and control records1 of 4
- 21 CFR 211.192Production record review1 of 4
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003964498 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003964498. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.