AFAM Concept, Inc.
7401 S Pulaski Rd, Chicago, Illinois, United States
FEI 3003818194
FDA has 4 inspections on file for AFAM Concept, Inc. in Chicago, Illinois (FEI 3003818194), from 2008 to 2021. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Seven regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 4, 2008–2021
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance15 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Description of containers, labels, et. al.
Master production and control records lack a description of the drug product containers, closures and packaging materials, a specimen or copy of each label and all other labeling, and the signatures and dates entered by the person or persons responsible for the approval of labeling.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Weights and measures of components used
Batch production and control records do not include the weights and measures of components used in the course of processing each batch of drug product produced.
Written distribution procedure
Written distribution procedures are not established.
Show 10 more citations
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing.
Labeling control records including specimens or copies
Batch production and control records do not include complete labeling control records, including specimens or copies of all labeling used for each batch of drug product produced.
Component written specification
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Records fail to include
Records kept for each different labeling and packaging material shipment fail to include results of examination or testing.
Written warehousing procedures established/followed
Procedures describing the warehousing of drug products are not established.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling and testing of components.
Written calibration procedures
Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions, schedules, and limits for accuracy and precision.
Container/Closure Description
The batch production and control records are deficient in that they do not include a description of drug product containers and closures.
Acceptance of drug products
Determinations of conformance to appropriate written specifications for acceptance are not made for drug products.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance25 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written procedures followed
Procedures for the preparation of master production and control records are not described in a written procedure.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Quality control unit review of records
Drug product production and control records, are not approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Batch production and Batch Control Record Requirements
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Show 20 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
No written record of investigation
Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and packaging of the drug product.
Individual inventory record
Records fail to include an individual inventory record of each component, drug product container, and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Approval and review of procedures
Written procedures are not drafted, reviewed and approved by the appropriate organizational units and reviewed and approved by the quality control unit.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Packaging line inspection after use
Inspection of the packaging and labeling facilities is not done after use to assure that materials not suitable for subsequent operations have been removed.
Packaging line inspection before use
Inspection of the packaging and labeling facilities immediately before use is not done to assure that all drug products have been removed from previous operations.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components.
Establishment of calibration procedures
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Written calibration procedures
Written calibration procedures for instruments, apparatus, gauges, and recording devices are deficient in that they do not include specific directions, schedules, and provisions for remedial action if limits are not met.
Distribution Recall System
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include assignment of responsibility, maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used, instructions for removal or obliteration of previous batch identification, and instructions for protection of clean equipment from contamination prior to use.
Adequate lab facilities not available
Adequate lab facilities for testing and approval or rejection of components and drug product containers are not available to the quality control unit.
Records fail to include
Records kept for each different labeling and packaging material shipment fail to include results of examination or testing and a statement of whether the shipment was accepted or rejected.
Component addition checked by 2nd person
Each component is not added to a batch by one person and verified by a second person.
Written procedures describing in detail
There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, and examination of labeling and packaging materials.
Regulations FDA cited here
The 19 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.80General requirements2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.122Materials examination and usage criteria2 of 2
- 21 CFR 211.150Distribution procedures2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.186Master production and control records2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
Show all 19
- 21 CFR 211.198Complaint files2 of 2
- 21 CFR 211.25Personnel qualifications1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
- 21 CFR 211.101Charge-in of components1 of 2
- 21 CFR 211.103Calculation of yield1 of 2
- 21 CFR 211.130Packaging and labeling operations1 of 2
- 21 CFR 211.142Warehousing procedures1 of 2
- 21 CFR 211.166Stability testing1 of 2
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 2
- 21 CFR 211.192Production record review1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003818194 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003818194. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.