Istituto De Angeli Srl
Localita Prulli 103/C, Reggello, Italy
FEI 3003697103DUNS 436912369
FDA has 3 inspections on file for Istituto De Angeli Srl in Reggello, Italy (FEI 3003697103), from 2014 to 2022. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
6 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and analysis, through Dec 31, 2027. Its registrant is ISTITUTO DE ANGELI SRL (D-U-N-S 436912369).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2014–2022
- 0 OAI · 3 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- 6 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
Sampling and testing procedures described
Written specifications for laboratory controls do not include a description of the testing procedures used.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Computer control of master formula records
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Extent of discrepancy, failure investigations
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.
Show 2 more citations
Review of problem drugs
The procedures for the annual quality standards record evaluation are deficient in that they do not address a review of complaint and investigation records for each drug product.
Complete test data included in records
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.194Laboratory records1 of 1
- 21 CFR 211.198Complaint files1 of 1
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003697103, one row per refused product line.
6 refusals from 2017-05-24 to 2025-06-30 · charged UNAPPROVED on 3, NOT LISTED on 3 · no FDA sample analysis
FDA firm profile- 2025-06-30
MISCELLANEOUS PATENT MEDICINES, ETC.66VDY99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsAEK-8554881-4/22/1
- 2022-08-26
BISACODYL (CATHARTIC)63HAA01
NOT LISTED 502(o), 801(a)(3); MISBRANDING
Division of Southeast Imports231-7817463-3/31/1
- 2020-12-08
ANTI-CHOLINERGIC, N.E.C.61KCM99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-9748008-0/11/2
- 2020-10-16
AMMONIUM CHLORIDE (ACIDIFIER)60BBB01
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-8069959-7/11/1
- 2017-05-24
PHENYLEPHRINE HCL (ADRENERGIC)60CCA09
NOT LISTED 502(o), 801(a)(3); MISBRANDING
DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING
Division of Northeast ImportsJ37-0009050-2/101/1D
Show 1 more
- 2017-05-24
TRAMAZOLINE HCL (ADRENERGIC)60CAL11
NOT LISTED 502(o), 801(a)(3); MISBRANDING
DIRECTIONS 502(f)(1), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
NO ENGLISH 502(c); 801(a)(3) ;MISBRANDING
Division of Northeast ImportsJ37-0009050-2/101/1C
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- ISTITUTO DE ANGELI SRLD-U-N-S 436912369
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003697103 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003697103. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.