Skip to content

Healz-Plus, Inc.

101 Advent St, Sulphur, Louisiana, United States

FEI 3003657823

FDA has one inspection on file for Healz-Plus, Inc. in Sulphur, Louisiana (FEI 3003657823). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published 19 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2011
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance19 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Written procedures describing in detail

      There is a lack of written procedures describing in sufficient detail the receipt, identification, storage, handling, sampling, examination, and testing of labeling and packaging materials.

    2. Representative Samples

      Representative samples are not taken of each shipment of each lot of components, drug product containers, and closures for testing or examination.

    3. Written procedures followed

      Procedures for the preparation of master production and control records are not described in a written procedure.

    4. Examination on receipt, before acceptance

      Each container or grouping of containers of components, drug product containers, and closures is not examined visually upon receipt and before acceptance for appropriate labeling as to contents, container damage, broken seals, and contamination.

    5. Procedures Written and Followed

      Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.

    Show 14 more citations
    1. Approval and review of procedures

      Written procedures are not reviewed and approved by the quality control unit.

    2. Procedures are written, and followed

      Procedures designed to assure that correct labels, labeling, and packaging materials are used for drug products are not written.

    3. Examination of issued labels

      Labeling materials issued for a batch were not carefully examined for identity and conformity to the labeling specified in the master or batch production records.

    4. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    5. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    6. Written distribution procedure

      Written distribution procedures are not established.

    7. Written warehousing procedures established/followed

      Procedures describing the warehousing of drug products are not established.

    8. Items to cover on annual reviews

      Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.

    9. Representative samples after completion

      Samples of representative units were not visually examined for correct labeling at the completion of finishing operations.

    10. Written records kept in individual logs

      Written records of major equipment cleaning, maintenance, and use are not included in individual equipment logs.

    11. Prepared for each batch, include complete information

      Batch production and control records are not prepared for each batch of drug product produced.

    12. Quarantine Storage of Components

      Incoming components, drug product containers, and closures are not stored under quarantine until they have been tested or examined, as appropriate, and released.

    13. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    14. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are not written or followed.

Regulations FDA cited here

The 15 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Show all 15

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3003657823 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3003657823. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.