Wayne Chemical Inc.
7114 Homestead Rd, Fort Wayne, Indiana, United States
FEI 3003583982
FDA has 2 inspections on file for Wayne Chemical Inc. in Fort Wayne, Indiana (FEI 3003583982), from 2010 to 2012. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 6 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.170(b) and 21 CFR 211.22(d).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2010–2012
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Test results, comparison with standards not included
Laboratory records do not include a statement of the results of tests and how the results compare with established standards of identity, strength, quality, and purity for the drug product tested.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are not written or followed.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Show 1 more citation
Procedures are written, and followed
Procedures designed to assure that correct labels are used for drug products are not written.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reserve samples identified, representative, stored
Reserve drug product samples are not representative of each lot or batch of drug product.
Buildings not maintained in good state of repair
Buildings used in the packing of a drug product are not maintained in a good state of repair.
Individual inventory record
Records fail to include an individual inventory record of each drug product container and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written and followed.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Show 3 more citations
Identity of major equipment and lines used
Batch production and control records do not include the identity of individual major equipment and lines used for each batch of drug product produced.
Written records kept in individual logs
Written records of major equipment cleaning are not included in individual equipment logs.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.170Reserve samples2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
- 21 CFR 211.58Maintenance1 of 2
- 21 CFR 211.125Labeling issuance1 of 2
- 21 CFR 211.130Packaging and labeling operations1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 2
Show all 10
- 21 CFR 211.194Laboratory records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003583982 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003583982. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.