Thornton Industries, Inc.
2000 Ashley Rd, Morris, Illinois, United States
FEI 3002837627
FDA has 4 inspections on file for Thornton Industries, Inc. in Morris, Illinois (FEI 3002837627), from 2009 to 2020. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.84(d)(2) and 21 CFR 211.165(a).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2009–2020
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Label storage access limited to authorized personnel
Access to the storage area for labels and labeling materials is not limited to authorized personnel.
Sampling and testing plans not described
Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
Mixing adequacy
The in process control procedures were deficient in that they did not include an examination of the adequacy of mixing to assure uniformity and homogeneity.
Component identification test
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the prior to release.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Written calibration / inspection records not kept
Records of the of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Accurate reproduction included
Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Show 1 more citation
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.165Testing and release for distribution3 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 3
- 21 CFR 211.22Responsibilities of quality control unit1 of 3
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 3
- 21 CFR 211.122Materials examination and usage criteria1 of 3
- 21 CFR 211.160General requirements1 of 3
Show all 10
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.188Batch production and control records1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002837627 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002837627. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.