ASI Marketing Group, LLC
826 S Commerce St, Las Vegas, Nevada, United States
FEI 3002442630
FDA has 4 inspections on file for ASI Marketing Group, LLC in Las Vegas, Nevada (FEI 3002442630), from 2009 to 2018. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 4 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Four regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2009–2018
- 0 OAI · 4 VAI · 0 NAI
- Inspections with 483 observations shown
- 4 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Control procedures to monitor and validate performance
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Review of representative number of batches
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration/Inspection/Checking not done
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Reports of Analysis (Components)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include parameters relevant to the operation.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the identification of components, drug product containers, and closures.
Identity Testing of Each Component
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Written calibration / inspection records not kept
Records of the calibration checks of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Approval and review of procedures
Written procedures are not reviewed and approved by the quality control unit.
GMP Training Frequency
GMP training is not conducted on a continuing basis to assure that employees remain familiar with CGMP requirements applicable to them.
Review of representative number of batches
Written procedures are not established for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected.
Show 3 more citations
Distinctive ID or code not recorded in batch record
The batch records do not record the distinctive identification number to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
Changes to Procedures Not Reviewed, Approved
Changes to written procedures are not reviewed and approved by the quality control unit.
Yield calculations not verified by 2nd person
Yield calculations are not performed by one person and independently verified by a second person.
Regulations FDA cited here
The 12 sections of 21 CFR in FDA’s published citations for this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures3 of 4
- 21 CFR 211.68Automatic, mechanical, and electronic equipment2 of 4
- 21 CFR 211.110Sampling and testing of in-process materials and drug products2 of 4
- 21 CFR 211.180General requirements2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.25Personnel qualifications1 of 4
- 21 CFR 211.67Equipment cleaning and maintenance1 of 4
- 21 CFR 211.80General requirements1 of 4
Show all 12
- 21 CFR 211.100Written procedures; deviations1 of 4
- 21 CFR 211.103Calculation of yield1 of 4
- 21 CFR 211.105Equipment identification1 of 4
- 21 CFR 211.160General requirements1 of 4
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002442630 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002442630. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.